[F] Kmd-900Mrh - Hoshizaki KMD-900MRH Service Manual

Hide thumbs Also See for KMD-900MRH:
Table of Contents

Advertisement

[f] KMD-900MRH

APPROXIMATE ICE
PRODUCTION PER 24 HR.
lbs./day kg./day
APPROXIMATE ELECTRIC
CONSUMPTION
watts
APPROXIMATE WATER
CONSUMPTION PER 24 HR.
3
gal./day
m
/day
FREEZING CYCLE TIME
min.
HARVEST CYCLE TIME
min.
HEAD PRESSURE
2
PSIG
kg/cm
G
SUCTION PRESSURE
2
PSIG
kg/cm
G
TOTAL HEAT OF REJECTION FROM CONDENSER
TOTAL HEAT OF REJECTION FROM COMPRESSOR
CONDENSER VOLUME
Note: Pressure data is recorded at 5 minutes into freeze cycle. The data not in bold
should be used for reference only.
We reserve the right to make changes in specifications and design without prior
notice.
AMBIENT TEMP.
(ºF/ºC)
70/21
906
80/27
885
90/32
878
100/38
857
70/21
80/27
90/32
100/38
70/21
465
80/27
421
90/32
407
100/38
338
70/21
80/27
90/32
100/38
70/21
80/27
90/32
100/38
70/21
210
80/27
219
90/32
222
100/38
226
70/21
26
80/27
28
90/32
28
100/38
30
51
WATER TEMP. (ºF/ºC)
50/10
70/21
411
878
401
842
398
812
389
795
2075
2117
2107
2173
2117
2220
2122
2230
1.76
407
1.59
330
1.54
266
1.28
261
13
13
13
14
13
15
14
15
2.7
2.5
2.6
2.2
2.5
2.0
2.3
2.0
14.8
222
15.4
237
15.6
250
15.9
255
1.8
28
2.0
31
2.0
34
2.1
35
12,100 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]
2,000 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]
132 CU. IN (URC-12F)
90/32
398
814
369
382
763
346
368
737
335
360
669
303
2162
2211
2262
2300
1.54
372
1.41
1.25
321
1.21
1.01
245
0.93
0.99
226
0.86
14
15
16
17
2.0
2.0
2.0
2.0
15.6
240
16.9
16.7
257
18.1
17.6
270
19.0
17.9
288
20.2
2.0
34
2.4
2.2
38
2.7
2.4
40
2.8
2.5
46
3.2

Hide quick links: