[C] Kmd-700Mrh - Hoshizaki KMD-900MRH Service Manual

Hide thumbs Also See for KMD-900MRH:
Table of Contents

Advertisement

[c] KMD-700MRH

APPROXIMATE ICE
PRODUCTION PER 24 HR.
lbs./day kg./day
APPROXIMATE ELECTRIC
CONSUMPTION
watts
APPROXIMATE WATER
CONSUMPTION PER 24 HR.
3
gal./day
m
/day
FREEZING CYCLE TIME
min.
HARVEST CYCLE TIME
min.
HEAD PRESSURE
2
PSIG
kg/cm
G
SUCTION PRESSURE
2
PSIG
kg/cm
G
TOTAL HEAT OF REJECTION FROM CONDENSER
TOTAL HEAT OF REJECTION FROM COMPRESSOR
CONDENSER VOLUME
Note: Pressure data is recorded at 5 minutes into freeze cycle. The data not in bold
should be used for reference only.
We reserve the right to make changes in specifications and design without prior
notice.
AMBIENT TEMP.
(ºF/ºC)
70/21
730
80/27
719
90/32
715
100/38
690
70/21
80/27
90/32
100/38
70/21
385
80/27
348
90/32
336
100/38
277
70/21
80/27
90/32
100/38
70/21
80/27
90/32
100/38
70/21
215
80/27
221
90/32
222
100/38
226
70/21
35
80/27
36
90/32
36
100/38
37
WATER TEMP. (ºF/ºC)
50/10
331
715
326
696
324
679
313
662
1750
1759
1762
1765
1.46
336
1.32
272
1.27
218
1.05
212
17
18
18
18
3.3
3.0
2.9
2.5
15.1
222
15.5
232
15.6
240
15.9
244
2.5
36
2.5
38
2.6
40
2.6
41
12,100 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]
1,900 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]
132 CU. IN (URC-12F)
48
70/21
90/32
324
655
316
614
308
605
300
538
1762
1777
1777
1792
1790
1806
1794
1820
1.27
303
1.03
257
0.82
195
0.80
174
18
19
20
20
2.9
2.4
2.0
2.0
15.6
236
16.3
248
16.9
256
17.1
270
2.6
39
2.7
41
2.8
43
2.9
45
297
278
275
244
1.15
0.97
0.74
0.66
20
21
22
24
2.0
2.0
2.0
2.0
16.6
17.5
18.0
19.0
2.7
2.9
3.0
3.2