Product Specifi C Information; Appliance Certifi Cation; Glass Specifi Cations; Btu Specifi Cations - Majestic fireplaces MDVI30IN Owner's Manual

Ruby series
Hide thumbs Also See for MDVI30IN:
Table of Contents

Advertisement

2 2
Product Specifi c Information
A. Appliance Certifi cation
MODELS: MDVI30IN, MDVI35IN
LABORATORY: Underwriters Laboratories, Inc. (UL)
TYPE: Direct Vent Heater
STANDARD: ANSI Z21.88-2014 • CSA 2.33-2014
This product is listed to ANSI standards for "Vented Gas
Fireplace Heaters" and applicable sections of "Gas Burn-
ing Heating Appliances for Manufactured Homes and
Recreational Vehicles", and "Gas Fired Appliances for
Use at High Altitudes".
Majestic gas inserts are designed for installations into solid
fuel masonry or factory built fi replaces that have been in-
stalled in accordance with the National, Provincial, State
and local building codes. Fireplaces are to be constructed
of non-combustible materials and, in the absence of local
or regional codes, meet criteria of NFPA 211. No additional
outside air source is required.
NOTICE: This installation must conform with local codes.
In the absence of local codes you must comply with the
National Fuel Gas Code, ANSI Z223.1-latest edition in
the U.S.A. and the CAN/CGA B149 Installation Codes in
Canada.
NOT INTENDED FOR USE AS A PRIMARY HEAT SOURCE.
This appliance is tested and approved as either supplemen-
tal room heat or as a decorative appliance. It should not be
factored as primary heat in residential heating calculations.
Installation and service of this appliance should be
performed by qualifi ed personnel. Hearth & Home
Technologies suggests NFI certifi ed or factory
trained professionals, or technicians supervised by
an NFI certifi ed professional (www.nfi certifi ed.org).
B. Glass Specifi cations
This appliance is equipped with 5 mm ceramic glass. Re-
place glass only with 5 mm ceramic glass. Please contact
your dealer for replacement glass.
6
Majestic • MDVI30IN, MDVI35IN Owner's Manual • 2205-981 Rev. D • 8/16
C. BTU Specifi cations
Models
(U.S. or Canada)
US
(0-2000 FT)
MDVI30IN (NG)
CANADA
(2000-4500 FT)
US
(0-2000 FT)
MDVI30IN (LP)
CANADA
(2000-4500 FT)
US
(0-2000 FT)
MDVI35IN (NG)
CANADA
(2000-4500 FT)
US
(0-2000 FT)
MDVI35IN (LP)
CANADA
(2000-4500 FT)
Maximum
Minimum
Orifi ce
Input
Input
Size
BTU/h
BTU/h
(DMS)
30,500
17,000
#36
28,000
15,000
#37
27,500
14,500
#52
25,000
13,000
#53
35,000
19,500
#33
32,500
17,500
#34
31,500
16,500
#51
27,500
15,000
#52

Hide quick links: