Cabinet Operation - Serene HB300 Operating And Service Manual

Single door vertical cooler
Table of Contents

Advertisement

2
OPERATION

2.2 Cabinet Operation

Before Operating
Before operating the cooler, ensure:
• the cooler is positioned on a level surface.
• that the maximum operating conditions are 40°C at 75% RH.
• there is adequate ventilation around the refrigeration unit.
• there is a gap of at least 35mm behind the cabinet.
• the rubber door stop is removed from the bottom lock bracket.
• both front stabiliser feet are screwed firmly down to floor level.
• both stand-off stops are fitted to the rear of the cabinet.
• the plastic drain pin is fitted in the drain hole in the cabinet liner
bottom.
• the cooler is allowed to stand for at least 30 minutes before
connecting to the power supply.
Connect the cabinet to the mains power supply and check operation
of the refrigeration unit and cabinet lighting.
Refrigeration Unit
The refrigeration unit evaporator and condenser fans should all
operate continuously from the time the cabinet is plugged in. This
may be verified by checking air movement inside the cabinet and out
of the top of the front kick panel.
Cabinet Lighting
The sign light and cabinet interior light will both go on when the
cabinet is plugged in, and will stay on permanently. The fluorescent
lights will require a period of time to stabilise following initial start up.
See pages 10-11 for instructions on replacing the fluorescent tubes.