Kenwood KDC-BT7539U Service Manual page 9

Hide thumbs Also See for KDC-BT7539U:
Table of Contents

Advertisement

MICROCOMPUTER'S TERMINAL DESCRIPTION
Pin No.
Pin Name
I/O
79
LX_REQ_M
O
79
NC
O
80
LX_MUTE
I
80
NC
O
81
LX_CON
O
81
NC
O
82
LX_RST
O
82
NC
O
83
MUTE_PRE_FR
O
84
MUTE_PRE_SW
O
85
PON_AM
I/O AM+B power supply control terminal
86
TUN_IFC_OUT
I
87
TUN_SMETER
I
88
RDS_NOISE
I
88
NC
O
89
RDS_AFS_M
I/O
89
NC
O
90
TYPE_1
I
90
NC
O
91
TYPE_2
I
91
NC
O
92,93 NC
O
94
AVSS
-
95
NC
O
96
VREF
-
97
AVCC
-
98
LX_DATA_S
I
98
NC
O
99
LX_DATA_M
O
99
NC
O
100
LX_CLK
I/O LX BUS clock
100
NC
O
Truth value table
q Destination setting
Type1
Model name
90
KDC-BT838U
1
KDC-BT8041U
1
KDC-BT8141UY
1
KDC-BT7539U
1
Application
Communication request to slave unit
Not used (Models not-supporting LX-BUS)
Mute request from slave unit
Not used (Models not-supporting LX-BUS)
Start-up request to slave unit
Not used (Models not-supporting LX-BUS)
Hardware-reset to slave unit
Not used (Models not-supporting LX-BUS)
External PREOUT_MUTE F/R
External PREOUT_MUTE SUB
MUTE_2 shock noise measure
F/E IFC OUT input terminal
S meter voltage detection terminal
FM noise voltage detection terminal
Not used (Models without RDS)
Time constant switching when noise is
detected
Not used (Models without RDS)
A/D 5 patterns
Not used (Models without USB)
A/D 5 patterns
Not used (Models without USB)
Not used
Not used
Data from slave unit
Not used (Models not-supporting LX-BUS)
Data to slave unit
Not used (Models not-supporting LX-BUS)
Not used (Models not-supporting LX-BUS)
Type1 (90)
Type2
Pull up
91
R645
1
×
5
×
4
×
2
×
KDC-BT7539U/BT8041U
/BT8141UY/BT838U
Truth
Processing Operation Description
value table
Output is fi xed to L
H: Mute ON, L: Mute OFF
Output is fi xed to L
H: Slave unit ON, L: Slave unit OFF
Output is fi xed to L
H: Reset, L: Normal
Output is fi xed to L
0bit, "L" during momentary power down
0bit, "L" during momentary power down
Use in addition to MUTE_2.
H: ON when receiving AM, Hi-Z: OFF in other cases
H: Station found, L: Station not found
Output is fi xed to L
L: During AF search, Hi-Z: In normal condition
Output is fi xed to L
q
Refer to "Destination table"
Output is fi xed to L
q
Refer to "Destination table"
Output is fi xed to L
Output is fi xed to L
Output is fi xed to L
Output is fi xed to L
Output is fi xed to L
Output is fi xed to L
Type2 (91)
Pull down
Pull up
R644
R643
22k
×
22k
22k
22k
22k
22k
47k
Pull down
Features
R642
22k
BT
BLUE
×
BT
BLUE
47k
BT
BLUE
22k
BT
BLUE
9

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kdc-bt8141uyKdc-bt838uKdc-bt8041u