Internal H2 Extension; Am1 Extension - Viessmann VITODENS 222-F Technical Manual

Gas condensing storage combi boiler
Table of Contents

Advertisement

Control units
(cont.)
Using the extension enables the following functions to be achieved:
Function
– Connection of an external safety solenoid valve (LPG)
And one of the following functions:
– Connection of a heating circuit pump for a directly connected heating circuit
– Connection of a central fault message
– Only for Vitotronic 200, type HO1B and HO2B:
Connection of a DHW circulation pump
Specification
Rated voltage
Rated frequency

Internal H2 extension

Part no. 7498 514
PCB for installation in the control unit, in place of the integral internal
H1 extension.
Using the extension enables the following functions to be achieved:
Function
– External extractor interlock
And one of the following functions:
– Connection of a heating circuit pump for a directly connected heating circuit
– Connection of a central fault message
– Only for Vitotronic 200, type HO1B and HO2B:
Connection of a DHW circulation pump
Power supply for DHW circulation pump
DHW circulation pumps with their own internal control unit must be
connected to a separate power supply. Mains connection via the
Vitotronic control unit or Vitotronic accessories is not permissible.

AM1 extension

Part no. 7452 092
Function extension inside enclosure for wall mounting.
Using the extension enables up to two of the following func-
tions to be achieved:
■ Switching the DHW circulation pump (only with Vitotronic 200,
type HO1B and HO2B)
■ Switching the heating circuit pump for a directly connected heating
circuit
6
■ Switching the circulation pump for cylinder heating (not for boilers
with integral DHW cylinder)
Power supply for DHW circulation pump
DHW circulation pumps with their own internal control unit must be
connected to a separate power supply. Mains connection via the
Vitotronic control unit or Vitotronic accessories is not permissible.
5 8
VIESMANN
86
230 V~
50 Hz
0
1 8
Rated breaking capacity of the relay output
Rated breaking capacity of the relay output
Specification
Rated voltage
230 V~
Rated frequency
50 Hz
Specification
Rated voltage
230 V~
Rated frequency
50 Hz
Rated current
4 A
Power consumption
4 W
Rated relay output break-
2(1) A, 250 V~ each, total max. 4 A~
ing capacity
Safety category
I
IP rating
IP 20 D to EN 60529, ensure through
design/installation
Permissible ambient temperature
– Operation
0 to +40 °C
Installation in living spaces or boiler
rooms (standard ambient conditions)
– Storage and transport
–20 to +65 °C
1(0.5) A 250 V~
2(1) A 250 V~
6(3) A 250 V~
2(1) A 250 V~
VITODENS