Viessmann VITODENS 222-F Technical Manual page 50

Gas condensing storage combi boiler
Table of Contents

Advertisement

Design information
Connection sets for installation on finished walls, for connection to the left or right
Connection set without pre-mounting bracket, part no. 7347 985
410
410
398
361
H
G
F
E
D
C
B
A
5
A Solar return R ¾/Ø 22 mm
B Heating flow R ¾
C DHW R ½
D Gas connection R ½
E DHW circulation R ½ (separate accessory)
Type
Vitodens 242-F, B2UB
Note
The adjustable feet give the height measurements of the connec-
tions a tolerance of + 7 mm.
For connecting the on-site gas, heating water and DHW lines from
the left or right.
VIESMANN
50
(cont.)
50
K
A
B
C
D
E
F
G
H
a
b
mm
mm
1367
1422
F Cold water R ½
G Heating return R ¾
H Solar flow R ¾/Ø 22 mm
K Balanced flue connection towards the back
c
d
e
mm
mm
mm
1477
1532
1587
Connection set comprising:
■ Connection pipes
■ Shut-off valves for heating water flow and return, with boiler drain
& fill valve
■ 2 connectors for DHW
■ 2 connectors each for solar flow and return (R¾/Ø 22 mm)
■ Gas shut-off valve with thermally activated safety shut-off valve
f
g
h
mm
mm
mm
1592
1696
1752
k
l
mm
mm
1807
2002
VITODENS