Fan Failures - Cisco 7200 VXR User Manual

Hide thumbs Also See for 7200 VXR:
Table of Contents

Advertisement

Chapter 1
Cisco 7200 VXR Product Overview
Following is sample output of the show environment all command:
NPE300(boot)# show environment all
Power Supplies:
Power supply 1 is unmeasured.
Power supply 2 is unmeasured.
Temperature readings:
chassis inlet
chassis outlet 1 measured at 28C/82F
chassis outlet 2 measured at 30C/86F
chassis outlet 3 measured at 30C/86F
Voltage readings:
+3.45 V measured at +3.45 V
+5.15 V is unmeasured
+12.15
-11.95
Envm stats saved 0 time(s) since reload

Fan Failures

When the system power is on, all three fans should be operational. The system
continues to operate if a fan fails; however, if the air temperature exceeds a
defined threshold, the system controller displays warning messages on the
console terminal, and if the temperature exceeds the shutdown threshold, the
system controller shuts down the system.
If the system does shut down because the temperature exceeded the shutdown
threshold, the system displays the following message on the console screen and
in the environment display when the system restarts:
Queued messages:
%ENVM-1-SHUTDOWN: Environmental Monitor initiated shutdown
For complete descriptions and instructions for the environmental monitor
commands, refer to the Configuration Fundamentals Configuration Guide and
Configuration Fundamentals Command Reference publications, which are
available on the Documentation CD-ROM or in print.
78-5469-03
measured at 28C/82F
is unmeasured
is unmeasured
Cisco 7200 VXR Installation and Configuration Guide
Functional Overview
1-69