Functional Overview
Table 1-22 Typical Processor-Monitored Temperature Thresholds (continued)
Parameter
NPE-100 or NPE-200
NPE-150
Table 1-23 Typical Power Supply-Monitored DC-Voltage Thresholds
Parameter
+3.45V
+5.15V
+12.15V
–11.95V
Reporting Functions
The Cisco 7200 VXR routers display warning messages on the console if chassis
interface-monitored parameters exceed a desired threshold. You can also retrieve
and display environmental status reports with the show environment, show
environment all, show environment last, and show environment table
commands. Parameters are measured and reporting functions are updated every
60 seconds. A brief description of each of these commands follows.
Cisco 7200 VXR Installation and Configuration Guide
1-66
High Warning
Chassis inlet
104 F (40 C)
Chassis outlet 1
109 F (43 C)
Chassis outlet 2
167 F (75 C)
Chassis outlet 3
122 F (50 C)
Chassis inlet
104 F (40 C)
Chassis outlet 1
109 F (43 C)
Chassis outlet 2
167 F (75 C)
Chassis outlet 3
131 F (55 C)
Low Critical
+3.26V
+4.86V
+11.39V
–9.52V
Chapter 1
Cisco 7200 VXR Product Overview
High Critical
122 F (50 C)
127 F (53 C)
167 F (75 C)
140 F (60 C)
122 F (50 C)
127 F (53 C)
167 F (75 C)
149 F (65 C)
Low Warning
High Warning
+3.34V
+3.55V
+4.99V
+5.31V
+11.67
+12.62V
–10.73
–13.16V
Shutdown
—
136 F (58 C)
—
149 F (65 C)
—
136 F (58 C)
—
158 F (70 C)
High Critical
+3.63V
+5.43V
+12.91V
–14.38V
78-5469-03