Replacing floor nozzle parts
CAUTION
Keep screws away from children after
removing the base plate.
We recommend the use of original
Panasonic replacement parts.
1
Place the appliance in the horizontal
position by using the foot pedal and
turn it over exposing the underside.
2
Pull out the hose from the rear side of
the appliance.
Remove the 8 screws from the base
plate by means of a screwdriver and
lift it off.
3
Replace the beater bar assembly /
beater bar belt.
- To replace the beater bar assembly, lift it
up and release the beater bar belt from
the beater bar pulley.
Replace the beater bar assembly with a
new one and reassemble in the reverse
order.
Beater
bar belt
14
Base
plate
Beater bar assembly
- To replace the beater bar belt, lift the
beater bar assembly to remove the beater
bar belt.
Replace the beater bar belt with a new
one and reassemble in the reverse order.
Turn the beater bar assembly by hand
to ensure the belt have been seated
correctly.
Beater bar belt
4
Place the base plate back to its
original position and re-fasten the
screws securely.