Table of Contents

Advertisement

• If you need to extend the length of the power
cable, ensure you use suitably rated cable and
that sufficient power (12 V dc) is available at the
SeaTalkng® backbone's power connection.
Important: Be aware that the suitable fuse rating
for the thermal breaker or fuse is dependent on the
number of devices you are connecting.
More information
Raymarine recommends that best practice is
observed in all vessel electrical installations, as
detailed in the following standards:
• BMEA Code of Practice for Electrical and
Electronic Installations in Boats
• NMEA 0400 Installation Standard
• ABYC E-11 AC & DC Electrical Systems on Boats
• ABYC A-31 Battery chargers and Inverters
• ABYC TE-4 Lightning Protection

Sharing a breaker

Where more than 1 piece of equipment shares a
breaker you must provide protection for the individual
circuits. E.g. by connecting an in-line fuse for each
power circuit.
1
2
3
4
Where possible, connect individual items of
equipment to individual circuit breakers. Where this
is not possible, use individual in-line fuses to provide
the necessary protection.
Warning: Product grounding
Before applying power to this product,
ensure it has been correctly grounded, in
accordance with the instructions provided.
Cables and connections
Positive (+) bar
Negative (-) bar
Circuit breaker
Fuse
Warning: Positive ground
systems
Do not connect this unit to a system which
has positive grounding.
25