3.12 OUT-OF-SERVICE PROCEDURE

3.12.1 REMOVAL FROM SERVICE
Prepare the generator for storage as follows:
1. Start the engine and let it run until it is thoroughly
warmed up (at least five minutes), then shut off the
engine.
2. While the engine is still warm from running, drain
the oil completely (see "Changing the Engine Oil
and/or Filter"). Refill the crankcase with the recom-
mended oil (see "Engine Oil Requirements").
3. Attach a tag to the engine, indicating the viscosity
and classification of the oil in the crankcase.
4. Remove the battery and store it in a cool, dry room
on a wooden board. Never store the battery on any
concrete or earthen floor.
5. Clean and wipe the entire generator.
3.12.2 RETURN TO SERVICE
To return the unit to service after storage, proceed as
follows:
1. Check the tag on the engine for oil viscosity and clas-
sification. Verify that the correct recommended oil is
used in the engine (see "Engine Oil Requirements").
If necessary, drain and refill with the proper oil.
2. Check the state of the battery. Fill all cells of
unsealed batteries to the proper level with distilled
water. DO NOT USE TAP WATER IN THE BATTERY.
Recharge the battery to 100 percent state of charge,
or, if defective, replace the battery.
3. Clean and wipe the entire generator.
4. Reconnect the battery. Observe battery polarity.
Damage may occur if the battery is connected incor-
rectly.
5. Turn OFF all electrical loads. Add fuel, if necessary,
and then start the engine.
6. Allow the unit to warm up thoroughly.
7. Apply electrical loads to at least 50 percent of the
unit's rated wattage capacity.
8. When the engine is thoroughly warmed up, shut it
down.
9. The generator is now ready for service.