Mounting The Nx-1200 - AMX NX-1200 Hardware Reference Manual

Integrated controller
Table of Contents

Advertisement

1.
Use the supplied #8-32 screws to secure the rack ears to the sides of the controller. You can attach the rack ears toward the
front or rear panel for either a front-facing or rear-facing installation.
2.
Slide the unit into the rack until the attachment holes, along both sides, align to their corresponding locations on the mounting
brackets, as shown in FIG. 6.
Mounting Integrated Controller into an equipment rack
FIG. 6
3.
Thread the cables through the opening in the equipment rack. Allow for enough slack in the cables to accommodate for
movement during the installation process.
4.
Reconnect all cables to their appropriate source/terminal locations. Refer to the Wiring and Connections section on page 23
for more detailed wiring and connection information. Verify that the terminal end of the power cable is not connected to the
power supply before plugging in the 2-pin power connector (or AC power connector on the NX-4200.)
5.
Secure the controller to the rack by using the four #10-32 screws supplied in the kit.
6.
Apply power to the unit to complete the installation.

Mounting the NX-1200

Mounting options for the NX-1200 are as follows:
Rack mounting with an AVB-VSTYLE-RMK-1U, V Style Module Rack Mounting Tray (FG1010-720)

Surface mounting with an AVB-VSTYLE-SURFACE-MNT, V Style Single Module Surface Mount (FG1010-722)

Consult the Mounting Options for V Style Modules Quick Start Guide included with the respective mounting kit for instructions on
mounting the NX-1200. The NX-1200 also has rubber feet which you can apply to the bottom of the unit for table-top mounting.
Hardware Reference Guide - NX-Series NetLinx Integrated Controllers