Boiler model NUVOLA 3+ BS 40
Category
Rated heat input
Reduced heat input
Rated heat output
Reduced heat output
Max. water pressure in CH system
Storage boiler capacity
Expansion vessel capacity
Expansion vessel pressure
DHW production at outlet ∆T=30°C
DHW max. water pressure
DHW production at ∆T=25 °C
DHW production at ∆T=35 °C
Specific output (*)
Type
Flue duct diameter
Max. flue mass flow rate
Min. flue mass flow rate
Max. flue temperature
Min. exhaust temperature
Gas used
Natural gas feeding pressure G20
Butane supply pressure G30
Propane gas feeding pressure G31
Power supply voltage
Power supply frequency
Rated power supply
Net weight
Dimensions
Protection against humidity and water penetration (**)
(*) according to EN 625
(**) according to EN 60529
INSTRUCTIONS FOR FITTERS
37. TECHNICAL DATA
240 i
II
2H3+
kW
27,1
kW
11,9
kW
24,4
kcal/h
21.000
kW
10,4
kcal/h
8.900
bar
3
l
42
l
7,5
bar
0,5
l/30min
380
bar
8
l/min
14
l/min
10
l/min
16
—
B
11BS
mm
140
kg/s
0,022
kg/s
0,021
°C
110
°C
82
—
G20
—
G30-G31
mbar
20
mbar
28-30
mbar
37
V
230
Hz
50
W
115
kg
53
height
mm
950
width
mm
600
depth
mm
466
IP X5D
—
55
7217402.01 - en