Principle Structure Of Analogue Signal Conversion; Pressure Measurements; Temperature Measurements - Bosch MS 6 Manual

Engine control unit
Hide thumbs Also See for MS 6:
Table of Contents

Advertisement

4 | Prepare Data Base
5 Volt
3.01 kOhm pullup
PULLUP_"function"
MS6 sw.pullup:
CWPULLUP_"pin"
MS6 input
PIN_IN_U"function"
38 / 78

Principle structure of analogue signal conversion

input-voltage:
u"function"

Pressure measurements

The system offers a lot of different pressure channels, please see function de‐
scription input signal processing for details. For gradient and offset information
contact sensor manufacturer.
Example: Ambient Pressure
PAMB_OFF, PAMB_GRD
UPAMB_MIN, UPAMB_MAX
PAMB_DEF
FCPAMB
All other variables are named by the same rule, replace "pamb" by e.g. "poil" to
apply data for the oil pressure sensor.

Temperature measurements

The system offers a lot of different temperature channels, please see function de‐
scription input signal processing for details.
Example: Intake Air Temperature
UTINT_MIN, UTINT_MAX
sensor o set
sensor gradient
„function" _OFF
„function" _GRD
_
2 point- and o set adjustment for
determination of sensor values
CW"function"CAL: choice of adjustment
„function"CAL/Pos1/Pos2: value of adj.
sensor mapping line (R)
function_CONV
Sensor offset and gradient
Minimum and maximum accepted sen‐
sor voltage. When violated, an error is
set (E_pamb = 1).
Default value if an error occurred.
Filter constant. For ambient pressure
use 1 second, for other pressures
choose appropriate values, ~ 100 ‐ 200
milliseconds
Minimum and maximum accepted sen‐
sor voltage. When violated, an error is
set (E_tint = 1).
ECU MS 6
phys. converted
/
measure channel
phys. converted
measure channel
phys. converted
measure channel
Bosch Motorsport

Hide quick links: