Safety Distance (S) - Miele DA 6700 D Operating And Installation Instructions

Hide thumbs Also See for DA 6700 D:
Table of Contents

Advertisement

a Mains connection cable

Safety distance (S)

The minimum distances between the top of a cooktop (excluding trivets, dials -
depending on model) and the bottom of the rangehood are as follows, unless a
greater distance is specified by the manufacturer of your cooking appliance.
See also "Warning and Safety instructions".
Cooking appliance
Electric cooktop
Electric grill, deep fat fryer (electric)
Multi-burner gas cooktop with maximum 45.4 MJ/h
total output, with no burner having a greater output than
16.2 MJ/h.
Multi-burner gas cooktop with total output greater than
45.4 MJ/h, but with a maximum of 77.8 MJ/h, with no
burner having a greater output than 17.3 MJ/h.
Multi-burner gas cooktop with total output greater than
77.8 MJ/h, with a single burner having a greater output
than 17.3 MJ/h.
Single burner gas cooktop with a maximum output of
21.6 MJ/h.
Single burner gas cooktop with an output greater than
21.6 MJ/h, but with a maximum of 29.2 MJ/h.
Single burner gas cooktop with an output greater than
29.2 MJ/h.
Installation
Minimum distance S
600 mm
650 mm
650 mm
760 mm
Not possible
650 mm
760 mm
Not possible
33

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents