Replacing The Engine Air Filter; Replacing The Avr Filter - Generac Power Systems 15 kW EcoGen Owner's Manual

60 hz air cooled generators
Hide thumbs Also See for 15 kW EcoGen:
Table of Contents

Advertisement

Maintenance

Replacing the Engine Air Filter

1. With the generator shut down, lift the lid and
remove the front panel.
2. See
Figure
4-10. Remove the cover clip (A) and
air cleaner cover (B).
A
Figure 4-10. Removing the Air Cleaner Cover
3. See
Figure
4-11. Pull out the old air filter (C) and
discard.
Figure 4-11. Removing the Air Filter
4. Thoroughly clean the air cleaner enclosure of any
dust or debris.
5. Install a new air filter.
6. Install the air cleaner cover and cover clip.
26

Replacing the AVR Filter

B
001221
Figure 4-12. Removing the AVR Filter Screw
C
001222
1. See
filter housing from back panel.
2. Remove AVR filter housing.
3. See
remove filter from filter housing.
4. Install new filter, so that edge is positioned inboard
of two tabs on filter housing.
5. Install AVR filter housing so the bottom drops into
the slots, ensuring that the rubber boot is
completely around the fan opening. Install screw to
fasten AVR filter housing to back panel and torque
to 50–96 in-lbs (6–11 Nm).
WARNING
Electric shock. AVR maintains electrical
charge after generator shutdown. Wait five
minutes before AVR removal. Failure to do
so could result in death or serious injury.
Figure 4-13. Replacing the AVR Filter
Figure
4-12. Remove screw to release AVR
Figure
4-13. Grasp rubber lifting strap and
Owner's Manual for 60 Hz EcoGen™ Generator
(000223)
001219
001220