Desa VSGF28NTF Owner's Operation And Installation Manual page 9

Unvented (vent-free) gas fireplace system
Hide thumbs Also See for VSGF28NTF:
Table of Contents

Advertisement

WARNING: These models have
a three-prong, grounded electrical
plug. This plug helps protect you
against electrical shock. Only con-
nect plug to a properly grounded,
three-prong receptacle. Do not cut
or remove the grounding prong
from this plug.
CAUTION: This fireplace cre-
ates warm air currents. These
currents move heat to wall sur-
faces next to fireplace. Installing
fireplace next to vinyl or cloth
wall coverings or operating
heater where impurities (such
as, but not limited, to tobacco
smoke, aromatic candles, clean-
ing fluids, oil or kerosene lamps,
etc.) in the air exist, may discolor
walls or cause odors.
Note: Your fireplace is designed to be used in
zero clearance installations. Wall or framing ma-
terial can be placed directly against any exterior
surface on the rear, sides or top of your fireplace,
except where standoff spacers are integrally at-
tached. If standoff spacers are attached to your
fireplace, these spacers can be placed directly
against wall or framing materials.
Use the dimensions shown for rough openings
to create the easiest installation. See Built-In
Fireplace Installation, page 12.
IMPORTANT: Vent-free heaters add moisture
to the air. Although this is beneficial, installing
fireplace in rooms without enough ventilation
air may cause mildew to form from too much
moisture. See Air for Combustion and Ventila-
tion, page 6.
IMPORTANT: Make sure the fireplace is level.
If fireplace is not level, log set will not work
properly.
CHECK GAS TYPE
Use the correct gas type (natural or propane/
LP) for your fireplace. If your gas supply is not
correct, do not install fireplace. Call dealer
where you bought fireplace for proper type
fireplace.
119303-01E
insTallaTion
Continued
equipped for either natural gas
or propane/LP gas but not both.
Gas type is indicated on the rat-
ing plate. Field conversion is not
permitted.
ELECTRICAL HOOKUP
This fireplace has a blower assembly with an
electrical cord. The electrical cord is five feet
in length. You must locate fireplace within
reach of 120-volt grounded electrical outlet. If
not, you must install an electrical outlet within
reach of fireplace power cord. The GA3555
outlet accessory may be used for built-in
installation when a blower is installed.
INSTALLING HOOD
Install hood to rail already installed in fireplace
as shown in Figure 5. Use 3 Phillips screws
provided.
Hood
Screw
ASSEMBLING AND ATTACHING
OPTIONAL PERIMETER TRIM
(Included with Mantel Accessory)
IMPORTANT: If you are recessing the firebox
in a wall, do not attach trim at this time. See
Built-In Fireplace Installation, page 12.
Note: These instructions are for assembling
and attaching trim to fireplace.
1. Remove packaging from three pieces
of trim.
2. Locate four screws, two adjusting plates
with set screws, and two shims in the
hardware packet.
3. Align shim under adjusting plate as shown
in Figure 6, page 10.
4. Slide one end of adjusting plate/shim
in slot on mitered edge of top trim (see
Figure 6, page 10).
www.desatech.com
WARNING: This appliance is
Rail
Figure 5 - Installing Hood