12.3.6
How to Take Out Front Grille
Please follow the steps below to take out front grille if
necessary such as when servicing.
1
Set the vertical airflow direction louvers to the
horizontal position.
2
Remove the 2 caps (1.0 ~ 2.0HP) or 3 caps
(2.5HP) on the front grille as shown in the
illustration at right, and then remove the
3 (1.0 ~ 2.0HP) or 4 (2.5HP) mounting screws.
3
Pull the lower section of the front grille
towards you to remove the front grille.
When reinstalling the front grille, carry out
above step 2 - 3 in the reverse order.
12.3.7
Disposal of Outdoor Unit Drain Water
If a drain elbow is used, the unit should be placed
on a stand which is taller than 3 cm.
If the unit is used in an area where temperature
falls below 0°C for 2 or 3 days in succession, it is
recommended not to use a drain elbow, for the
drain water freezes and the fan will not rotate.
12.3.8
Check the Drainage
Open front panel and remove air filters. (Drainage
checking can be carried out without removing the
front grille.)
Pour a glass of water into the drain tray-styrofoam.
Ensure that water flows out from drain hose of the
indoor unit.
12.3.9
Evaluation of the Performance
Operate the unit at cooling/heating operation
mode for fifteen minutes or more.
Measure the temperature of the intake and
discharge air.
Ensure the difference between the intake
temperature and the discharge is more than 8°C
during Cooling operation or more than 14°C
during Heating operation.
Front grille
Vane
(Move the vane
to upward)
Drain elbow 7
Install the hose at an angle so that the
water smoothly fl ows out.