Model
Performance Test Condition
Power Supply
Capacity
Running Current
Input Power
Annual Consumption
EER
Pdesign
SEER
ErP
Annual
Consumption
Class
Power Factor
Indoor Noise (H / L / QLo)
Outdoor Noise (H / L)
Capacity
Running Current
Input Power
COP
Pdesign
Tbivalent
SCOP
ErP
Annual
Consumption
Class
Power Factor
Indoor Noise (H / L / QLo)
Outdoor Noise (H / L)
Low Temp. : Capacity (kW) / I.Power (W) / COP
Extr Low Temp. : Capacity (kW) / I.Power (W) / COP
Max Current (A) / Max Input Power (W)
Starting Current (A)
Indoor
Outdoor
Phase, Hz
V
Min.
kW
0.85
BTU/h
2900
Kcal/h
730
A
W
265
kWh
W/W
3.21
BTU/hW
10.94
Kcal/hW
2.75
kW
(W/W)
kWh
%
dB-A
Power Level dB
dB-A
Power Level dB
kW
0.80
BTU/h
2730
Kcal/h
690
A
W
200
W/W
4.00
BTU/hW
13.65
Kcal/hW
3.45
kW
°C
(W/W)
kWh
%
dB-A
Power Level dB
dB-A
Power Level dB
CS-TZ15SKEW
CU-TZ15SKE
EUROVENT
Single, 50
230
Mid.
Max.
4.20
4.60
14300
15700
3610
3960
5.60
1.26k
1.65k
630
3.33
2.79
11.35
9.52
2.87
2.40
4.2
5.6
263
A+
98
44 / 31 / 29
60 / –
49 / –
64 / –
5.00
6.80
17100
23200
4300
5850
6.00
1.35k
2.05k
3.70
3.32
12.67
11.32
3.19
2.85
3.6
-10
3.8
1326
A
98
44 / 35 / 28
60 / –
51 / –
66 / –
4.93 / 1.81k / 2.72
3.90 / 1.70k / 2.29
8.9 / 2.05k
6.00
13
CS-TZ18SKEW
CU-TZ18SKE
EUROVENT
Single, 50
230
Min.
Mid.
0.98
5.00
3340
17100
840
4300
7.20
285
1.62k
810
3.44
3.09
11.72
10.56
2.95
2.65
5.0
6.7
261
A++
98
44 / 37 / 34
60 / –
48 / –
63 / –
0.98
5.80
3340
19800
840
4990
7.90
340
1.76k
2.88
3.30
9.82
11.25
2.47
2.84
4.0
-10
4.1
1366
A+
97
44 / 37 / 34
60 / –
49 / –
64 / –
5.43 / 2.14k / 2.54
4.67 / 2.24k / 2.08
11.0 / 2.42k
7.90
Max.
5.40
18400
4640
1.80k
3.00
10.22
2.58
7.50
25600
6450
2.42k
3.10
10.58
2.67