TIMER FEATURES

Parameter
Display
Error/
Information
Icon
Service
Icon
Programming
Icon
Extra Cycle
Button
Figure 1
Features of the SXT:
• Power backup that continues to keep time and the
passage of days for a minimum of 48 hours in the event
of power failure. During a power outage, the control
goes into a power-saving mode. It does not monitor
water usage during a power failure, but it does store the
volume remaining at the time of power failure.
• Settings for both valve (basic system) and control type
(method used to trigger a regeneration).
• Day-of-the-Week controls.
• While in service, the display alternates between time of
day, volume remaining or days to regeneration, and tank
in service (twin tank systems only).
• The Flow Indicator flashes when outlet flow is detected.
• The Service Icon flashes if a regeneration cycle has
been queued.
• A Regeneration can be triggered immediately by
pressing the Extra Cycle button for five seconds.
• The Parameter Display displays the current Cycle Step
(BW, BF, RR, etc) during regeneration, and the data
display counts down the time remaining for that cycle
step. While the valve is transferring to a new cycle step,
the display will flash. The parameter display will identify
the destination cycle step (BW, BF, RR, etc) and the data
display will read "----". Once the valve reaches the cycle
step, the display will stop flashing and the data display
will change to the time remaining. During regeneration,
the user can force the control to advance to the next
cycle step immediately by pressing the extra
cycle button.
Data
PM
Display
Indicator
Flow Indicator
x1000 Indicator
42637 Rev D
Up
Down
Button
Button
Setting the Time of Day
1. Press and hold either the Up or Down buttons until the
programming icon replaces the service icon and the
parameter display reads TD.
2. Adjust the displayed time with the Up and Down buttons.
3. When the desired time is set, press the Extra Cycle button
to resume normal operation. The unit will also return to
normal operation after 5 seconds if no buttons are pressed.
Queueing a Regeneration
1. Press the Extra Cycle button. The service icon will flash to
indicate that a regeneration is queued.
2. To cancel a queued regeneration, press the Extra
Cycle button.
Regenerating Immediately
Press and hold the Extra Cycle button for five seconds.