Indoor Unit Error Display - Carrier 42QHC009DS Service Manual

15c inverter series
Hide thumbs Also See for 42QHC009DS:
Table of Contents

Advertisement

9.1 Indoor Unit Error Display

Operation
lamp
☆ 1 time
☆ 2 times
☆ 4 times
☆ 5 times
☆ 6 times
☆ 7 times
☆ 2 times
☆ 3 times
☆ 4 times
☆ 5 times
☆ 6 times
☆ 1 times
☆ 2 times
☆ 3 times
☆ 5 times
Timer lamp
Display
X
E0
X
E1
X
E3
X
E4
X
E5
X
EC
O
F1
O
F2
O
F3
O
F4
O
F5
P0
P1
P2
P4
O(light)
LED STATUS
Indoor unit EEPROM parameter error
Indoor / outdoor units communication error
Indoor fan speed has been out of control
Indoor room temperature sensor T1 open circuit or short
circuit
Evaporator coil temperature sensor T2 open circuit or
short circuit
Refrigerant leakage detection
Outdoor ambient temperature sensor T4 open circuit or
short circuit
Condenser coil temperature sensor T3 open circuit or
short circuit
Compressor discharge temperature sensor T5 open
circuit or short circuit
Outdoor unit EEPROM parameter error
Outdoor fan speed has been out of control
IPM malfunction or IGBT over-strong current protection
Over voltage or over low voltage protection
High temperature protection of compressor top
diagnosis and solution
Inverter compressor drive error
☆(flash)
X(off)
28