Download Print this page

Expanded Heating Data - Goodman SSZ16 Product Specifications

Hide thumbs Also See for SSZ16:

Advertisement

P
S
roduct
PecificationS
e
H
d
xPanded
eating
ata
SSZ160241A* / CA*F3636*6A* + TXV / MBE1600**-1
65
60
55
MBh
30.2
28.6
26.9
25.1
∆T
31.9
30.2
28.4
26.6
kW
1.79
1.75
1.72
1.68
Amps
8.4
7.8
7.3
COP
4.93
4.76
4.57
4.37
EER
16.9
16.3
15.6
14.9
Hi PR
349
334
322
307
Lo PR
144
133
125
115
SSZ160361A* / CA*F4860*6A*+TXV/ MBE2000**-1
65
60
55
MBh
43.2
40.9
38.5
36.0
∆T
33.4
31.6
29.7
27.8
kW
2.70
2.65
2.59
2.54
Amps
13.1
12.1
11.3
10.6
COP
4.68
4.52
4.35
4.15
EER
16.0
15.5
14.9
14.2
Hi PR
389
373
359
343
Lo PR
147
136
127
117
SSZ160481A* / CA*F4860*6A* + TXV / MBE2000**-1
65
60
55
MBh
59.1
55.9
52.6
49.2
∆T
35.3
33.4
31.4
29.4
kW
3.69
3.62
3.54
3.47
Amps
17.6
16.3
15.2
14.3
COP
4.68
4.52
4.35
4.15
EER
16.0
15.5
14.9
14.2
Hi PR
405
388
373
357
Lo PR
140
130
122
112
SSZ160601A* / CA*F4860*6A* + TXV / MBE2000**-1
65
60
55
MBh
71.6
67.8
63.8
59.7
∆T
36.9
34.9
32.8
30.7
kW
4.73
4.63
4.53
4.44
Amps
21.7
20.0
18.7
17.6
COP
4.44
4.29
4.12
3.94
EER
15.2
14.7
14.1
13.5
Hi PR
395
379
364
348
Lo PR
133
124
116
106
High pressure is measured at the suction service valve ( the larger valve).
Amps = Outdoor unit amps (comp.+fan)
kW = Total system power
12
Outdoor Ambient Temperature
50
47
45
40
35
24.0
23.3
21.6
19.9
25.4
24.6
22.9
21.1
1.7
1.65
1.62
1.58
6.9
6.7
6.6
6.2
5.9
4.22
4.13
3.91
3.69
14.4
14.1
13.4
12.6
300
295
283
272
108
104
96
85
Outdoor Ambient Temperature
50
47
45
40
35
34.4
33.3
31.0
28.6
26.5
25.7
23.9
22.0
2.5
2.48
2.43
2.37
10.3
10.1
9.5
9.0
4.02
3.93
3.73
3.52
13.7
13.4
12.7
12.0
335
329
316
303
110
106
98
87
Outdoor Ambient Temperature
50
47
45
40
35
47.0
45.5
42.3
39.0
28.1
27.2
25.3
23.3
3.4
3.40
3.32
3.25
13.8
13.5
12.7
12.1
4.01
3.93
3.72
3.51
13.7
13.4
12.7
12.0
348
342
328
315
106
102
94
83
Outdoor Ambient Temperature
50
47
45
40
35
57.0
55.2
51.3
47.3
29.3
28.4
26.4
24.3
4.4
4.34
4.25
4.15
16.9
16.6
15.6
14.8
3.81
3.73
3.54
3.34
13.0
12.7
12.1
11.4
340
334
321
308
101
97
89
79
www.goodmanmfg.com
30
25
20
17
18.7
17.3
15.9
15.0
19.8
18.3
16.8
15.9
1.68
1.64
1.60
1.58
5.7
5.4
5.2
5.1
3.26
3.08
2.91
2.79
11.2
10.5
9.9
9.5
260
249
239
233
77
69
60
56
30
25
20
17
26.2
24.2
22.2
21.0
20.2
18.6
17.2
16.2
2.46
2.40
2.34
2.31
8.6
8.2
7.9
7.7
3.12
2.95
2.78
2.67
10.6
10.1
9.5
9.1
291
277
266
260
78
70
62
57
30
25
20
17
35.4
32.6
30.1
28.4
21.1
19.5
18.0
17.0
3.14
3.06
2.99
2.95
11.5
11.0
10.5
10.2
3.30
3.12
2.94
2.82
11.3
10.7
10.0
9.6
302
288
277
270
75
67
59
55
30
25
20
17
44.9
41.4
38.1
36.0
23.1
21.3
19.6
18.5
4.27
4.16
4.06
4.00
14.1
13.5
12.8
12.5
3.08
2.91
2.75
2.63
10.5
9.9
9.4
9.0
295
282
270
264
71
64
56
52
Low pressure is measured at the gauge port connection.
Calculations are based on nominal CFM and 70 °F indoor dry bulb.
Shaded area is AHRI Rating Conditions at 47°F outdoor ambient temperature
15
10
5
0
-5
14.4
13.0
11.5
10.0
8.6
15.3
13.7
12.2
10.6
9.0
1.56
1.52
1.48
1.45
1.41
5.0
4.7
4.4
4.2
3.9
2.71
2.49
2.27
2.03
1.78
9.3
8.5
7.7
6.9
6.1
229
220
212
203
196
54
46
40
33
29
15
10
5
0
-5
20.2
18.1
16.1
14.0
12.0
15.6
14.0
12.4
10.8
9.2
2.28
2.22
2.16
2.11
2.05
7.6
7.2
6.7
6.3
5.8
2.59
2.39
2.17
1.95
1.71
8.9
8.2
7.4
6.7
5.8
255
246
236
227
218
55
47
40
34
30
15
10
5
0
-5
27.3
24.5
21.7
19.0
16.2
16.3
14.7
13.0
11.3
9.7
2.92
2.85
2.78
2.71
2.63
10.1
9.6
8.9
8.4
7.7
2.74
2.52
2.29
2.05
1.80
9.4
8.6
7.8
7.0
6.1
265
255
246
235
227
53
45
39
33
28
15
10
5
0
-5
34.7
31.1
27.6
24.0
20.5
17.8
16.0
14.2
12.4
10.6
3.96
3.86
3.76
3.66
3.55
12.3
11.6
10.8
10.2
9.3
2.56
2.36
2.15
1.92
1.69
8.7
8.1
7.3
6.6
5.8
259
249
240
230
222
50
43
37
31
27
SS-SSZ16
-10
7.0
7.4
1.37
3.5
1.50
5.1
189
23
-10
9.8
7.6
1.99
5.3
1.44
4.9
211
23
-10
13.3
7.9
2.56
6.9
1.51
5.2
219
22
-10
16.8
8.6
3.45
8.4
1.42
4.9
214
21

Hide quick links:

Advertisement

loading