Specifications - Crown MA-5002VZ Operation Manual

Hide thumbs Also See for MA-5002VZ:
Table of Contents

Advertisement

Macro-Tech MA-5002VZ Power Amplifier

7 Specifications

Minimum Guaranteed Power (see page 19 for complete power specifications)
120 VAC, 60 Hz Units, Stereo mode, per channel, both channels driven
1 kHz with 0.1% THD
Stereo, 2 ohms per ch
Stereo, 4 ohms per ch.
Stereo, 8 ohms per ch.
120 VAC, 60 Hz Units, Bridge Mono mode
1 kHz with 0.1% THD
4 ohms
8 ohms
16 ohms
120 VAC, 60 Hz Units, Parallel Mono mode
1 kHz with 0.1% THD
1 ohm
2 ohms
4 ohms
Performance
Frequency Response
(at 1 watt, 20Hz - 20 kHz) see Figure 7.3
Phase Response
(at 1 watt, 10Hz - 20 kHz) see Figure 7.6
Signal to Noise Ratio below full bandwidth power
20 Hz to 20 kHz
A-weighted
Total Harmonic Distortion (THD)
at rated power, true THD
Intermodulation Distortion (IMD)
60 Hz and 7 kHz at 4:1,from rated power to 35 dB below rated power at 8 ohms
Damping Factor
10 Hz to 400 Hz See Figure 7.4
Controlled Slew Rate
Crosstalk
Input Impedance nominally balanced, nominally unbalanced
Operation Manual
2,500
2,000
1,300
5,000
4,000
2,600
5,000
3,700
2,600
± 0.1 dB
±10°
>100 dB
>105 dB
<0.05%
<0.05%
>1000
>30 volts/µs
See Figure 7.7
20 k ohms, 10 k ohms