Series is the defi ning
®
®
standard for amplifi er design today. No compro-
mises, no gimmicks. Just brilliant engineering
backed by superior manufacturing, support and an
unsurpassed commitment to quality. Like all Crown
amps, the defi ning characteristic of the Macro-Tech
Features
crosstalk characteristics and the best power
Series is sonic accuracy. A tight, rock-solid low end,
matching to your load; in the MA-5002VZ, three
with smooth, detailed highs and a well-defi ned mid-
• Crown's Grounded Bridge™ design delivers
range. In short, the most accurate reproduction of an
special modes are provided to control how and
large voltage swings without using easily
audio signal you've ever heard. And because we put
when the supplies shift impedance modes
stressed output-transistor confi gurations like
the quality of sound above all else, a Crown amplifi er
conventional amplifi ers; the results are lower
Very low harmonic and intermodulation distor-
is the most coveted amplifi er in the business.
distortion and superior reliability
tion result in the best dynamic transfer function
When it comes to manufacturing amps, our work is
in the industry
®
Patented ODEP
(Output Device Emulation
based on one simple fact: there are no shortcuts to
Protection) circuitry compensates for over-
quality. And our Macro-Techs have proven it time and
MA-5002VZ only: Independent error-driven
time again in some of the most demanding applica-
heating and overload to keep the amplifier
compressor for each channel that can be set for
tions in the world.
working when others would fail
fast or slow attack and release times
®
The VZ
Series is a signifi cant leap forward in ampli-
IOC
®
(Input/Output Comparator) circuitry
Full protection from shorted, open and mis-
fi er design. Our patented variable impedance (VZ)
immediately alerts of any distortion exceeding
matched loads; general overheating; DC;
technology permits the MA-3600VZ or MA-5002VZ to
0.05%, providing dynamic proof of distortion-
high-frequency overloads; and internal fault
dynamically adapt to signal and load requirements in
free performance
conditions
real time. Whether you need current in a low-imped-
ance sub-woofer situation, or high-voltage swings for
MA-5002VZ accepts Crown PIP2 modules. MA-
Three-Year, No-Fault, Fully Transferable
those transient signals, the VZs deliver!
3600VZ accepts only the PIP-Lite module when
Warranty completely protects your investment
For more details about the Crown Macro-Tech
fi tted with the IQ-PIP-USP2 Adapter
and guarantees its specifi cations
Series, contact the Crown Technical Support Group
Patented Variable Impedance (VZ
®
)power
at 800-342-6939 or 574-294-8200. Also, visit the
supplies for each channel provide excellent
Crown Audio website at www.crownaudio.com.
Specifi cations
Note: Specifi cations relate to 120 volt, 60 Hz units
MA-5002VZ:
AC Line Connector:
in Stereo mode with 8-ohm loads and an input sen-
MA-3600VZ: NEMA TT30P.
132:1 ±12% or 42 dB ±1 dB gain at 0.775 volt
sitivity of 26 dB gain at 1 kHz rated power unless
sensitivity.
otherwise specifi ed. Specifi cations for units supplied
MA-5002VZ: 10 AWG cordset with NEMA TT30P
outside the U.S.A. may vary slightly at different AC
71:1 ±12% or 37 dB ±1 dB gain at 1.4-volt sensitiv-
plug is provided on 120VAC, 60 Hz North American
voltages and frequencies.
ity.
units.
Power
Performance
20:1 ±3% or 26 dB ±0.25 dB gain at the maximum
Output Power: See power charts below.
level setting.
Frequency Response: ±0.1 dB from 20 Hz to 20 kHz
Load Impedance: Safe with all types of loads, even reac-
at 1 watt.
Required AC Mains (MA-3600VZ): 50/60 Hz;
tive ones. MA-3600VZ is rated for 2 to16 ohms in Stereo.
100, 120, and 230VAC (±10%) units are available.
Phase Response: ±10 degrees from 10 Hz to 20 kHz
MA-5002VZ is rated for 2 to 8 ohms in Stereo. Both
230VAC, 50/60 Hz units can be used with 220 and
at 1 watt.
amplifi ers are rated for 4 to 16 ohms in Bridge-Mono and
240VAC. All versions draw 90 watts or less at idle.
Signal-to-Noise Ratio: > 105 dB A-weighted or 100
1 to 4 ohms in Parallel-Mono mode.
100VAC and 120VAC units can draw up to 30 amps;
dB unweighted below rated power, 20 Hz - 20 kHz.
230VAC units can draw up to 15 amps. Current,
Voltage Gain to 8 ohm load at rated output at 1 kHz,
Total Harmonic Distortion (THD):
voltage and frequency requirements are provided on
maximum level setting:
unit's back panel.
MA-3600VZ: At full bandwidth power, < 0.05%
MA-3600VZ:
from 20 Hz to 1 kHz increasing linearly to < 0.1%
Required AC Mains (MA-5002VZ): 50 or 60 Hz;
124.6:1 ±6% or 41.9 dB ±0.5 dB at 0.775 volt
at 20 kHz.
100, 120, 200, 208, 230, 240VAC (±10%). All units
sensitivity.
draw 90 watts or less at idle. Current, voltage and
MA-5002VZ: 1 kHz rated power, 0.05% or less true
69.2:1 ± 6% or 36.8 dB ±0.5 dB at 1.4 volt sensitiv-
frequency requirements are provided on unit's back
THD.
ity.
panel.
kHz
Intermodulation Distortion (IMD): (60 Hz and 7
20:1 ±6% or 26 dB ±0.5 dB at +26 dB sensitivity.
at 4:1)
MA-3600VZ: Less than 0.05% from 368 mil-
20 Hz–20 kHz
*
1 kHz
**
MA-5002VZ
liwatts to full bandwidth power.
Power
Power
*
1 kHz
MA-5002VZ: Less than 0.05% from rated power to
MA-3600VZ
2 ohm Dual (per ch.)
2,500W
2,155W
Power
35 dB below rated power at 8 ohms.
1,800W
2 ohm Dual (per ch.)
2,000W
1,775W
4 ohm Dual (per ch.)
Damping Factor: > 1,000 from 10 Hz to 400 Hz.
Slew Rate: (Slew rates are limited to useful levels for
1,300W
1,090W
1,565W
4 ohm Dual (per ch.)
8 ohm Dual (per ch.)
ultrasonic/RF protection.) > 30 volts per microsecond.
1,120W
5,000W
8 ohm Dual (per ch.)
4 ohm Bridge-Mono
Controls
3,505W
4,000W
3,670W
Compressor (MA-5002VZ only): A three-position
8 ohm Bridge-Mono
4 ohm Bridge-Mono
back-panel switch is used to control each channel's
3,140W
8 ohm Bridge-Mono
*1 kHz Power: refers to maximum average power in watts
input compressor. The "fast" setting provides an
at 1 kHz with 0.1% THD.
attack time of 4 milliseconds and a release time of
*1 kHz Power: refers to maximum average power in watts
**20 Hz–20 kHz Power: refers to maximum average power
300 milliseconds; the "slow" setting provides an
at 1 kHz with 0.1% THD.
in watts from 20 Hz to 20 kHz with 0.1% THD.

   Also See for Crown Macro-Tech MA-5002VZ

   Related Manuals for Crown Macro-Tech MA-5002VZ

   Summary of Contents for Crown Macro-Tech MA-5002VZ

  • Page 1

    In short, the most accurate reproduction of an audio signal you’ve ever heard. And because we put the quality of sound above all else, a Crown amplifi er is the most coveted amplifi er in the business. When it comes to manufacturing amps, our work is based on one simple fact: there are no shortcuts to quality.

  • Page 2

    And the coverage is transferable, should you sell your amplifi er. See your authorized Crown dealer for full warranty disclosure and details. For customers outside of the USA, please contact your authorized Crown distributor for warranty information or call 574-294-8200.

This manual also for:

Ma-5002vz, Ma-3600vz

Comments to this Manuals

Symbols: 0
Latest comments: