Symbology
Wire Feed (Speed)
Workpiece Ground Cable
Torch Cable
Overheat Shutdown Indicator
Cooling Fan
Housing Ground Point

Specifications

Power Input
Welding Output
Capacity
Rated Duty Cycle
Open Circuit Voltage
KVA
Wire Speed
Cable Sizes
Wire Spool Capacity
Accessories
Item 62181
240VAC / 60Hz / 24A
DCEN/DCEP
30-180A
18 gauge (0.048") to 5/16" (0.3125") mild steel
Not for welding aluminum
20% at 140A
(See explanation on page 16)
42
5.75
30 – 650 IPM
Ground: 6', 7 AWG
Torch: 6', 7 AWG
Power: 3-wire, 6' 5", 12 AWG
6-50P NEMA plug type
up to 10 lb spool
(one 1 lb spool of flux-core wire included)
Spare Welder Tips (one each for 0.023" and 0.030"– 0.035" wire)
Welding Face Shield
Combination Wire Brush / Chipping Hammer
For technical questions, please call 1-888-866-5797.
VAC
Volts Alternating Current
A
Amperes
OCV
Open Circuit Voltage
KVA
Kilovolt Amperes
(Volts / 1000 * Amperes)
IPM
Inches Per Minute
AWG
American Wire Gauge