Calling Up/Modifying Service Timer Settings; Calling Up/Modifying The Unit Of Temperature - Quincy Compressor QED-300 Instruction Book

Refrigerant compressed air dryers
Table of Contents

Advertisement

Instruction book

3.17 Calling up/modifying service timer settings

Calling up/modifying service timer settings
Starting from the Main screen:
• Press Scroll button (12) until <P. 4> is shown and then press Enter button (13): the setting of the service
timer is shown in <hrs> (hours) or <x1000 hrs> (hours x 1000). Example: <4000 hrs> means the timer is
set at 4000 running hours.
• Press Enter button (13) to modify this value (a password may be required): the value starts blinking. Use
the Scroll buttons (12) to modify the setting.
• Press Enter button (13) to program the new value.
• Press Escape button (14) to return to the parameter screen.

3.18 Calling up/modifying the unit of temperature

Calling up/modifying unit of temperature
Starting from the Main screen, press Scroll button (12) until <P. 5> is shown and then press Enter button (13).
The actually used unit is shown. Possible settings are <˚C> and <˚F>.