Pre-Installation Checklist; Preparing The Opening - Monogram ZEU36K Installation Instructions Manual

36" electric cooktop -radiant
Table of Contents

Advertisement

Available languages

Available languages

Installation
Instructions
PRE-INSTALLATION CHECKLIST
AWARNING
- The electrical
power to
the cooktop
supply line must be shut off while
connections
are being made. Failure to do so
could result in serious injury or death.
rA1
When preparing
cooktop
opening, make sure
the inside of the cabinet and the cooktop do
not interfere with each other. (See section on
preparing
the opening.)
r_
Remove packaging
materials
and literature
package from the cooktop before beginning
installation.
Literature
Package
(Located
under
unit)
Foam
Packaging
Cooktop
[]
Be sure to place all literature,
Owner's Manual,
Installations,
etc. in a safe place for future
reference.
rD]
Make sure you have all the tools and materials
.you need before starting the installation
of the
cooktop.
rE]
Your home must provide the adequate
electrical
service needed to safely and
properly
use your cooktop. (Refer to section on
electrical
requirements.)
D
Fa
[]
When installing your cooktop
in .your home,
make sure all local codes and ordinances
are
followed exactly as stated.
Make sure the wall coverings, countertop
and
cabinets around the cooktop can withstand
heat (up to 200°F) generated
by the cooktop.
Installing
cooktop
in combination
with other
products.
Both products
must be installed
according
to their specific product installation
instructions.
Consideration
must be given the
separate electrical requirements
and locations:
Over one or two wall ovens:
• Only certain models may be installed over
wall ovens. The wall oven and cooktop
will
both have a label stating which models are
approved
in combination.
Over a Microwave:
• See microwave
installation
instructions
for how to install a microwave
under a
cooktop. For vertical dimension
of cooktop,
see Approximate
Cooktop Dimensions
section.
In combination
with telescopic downdraft
vent:
• See telescopic
downdraft
vent instructions
for how to install a vent behind a cooktop.
• The countertop
must have a deep flat
surface to accommodate
the combined
installation
of the cooktop
and vent.
Over a warming
drawer:
• See warming
drawer instructions
for how to
install a warming
drawer under a cooktop.
For vertical dimension
of cooktop, see
Approximate
Cooktop Dimensions section.
PREPARING THE OPENING
rT]
The following
MINIMUM clearance
dimensions
must be maintained.
If a 30" clearance
between the cooking surface and
overhead
combustible
materials
or metal cabinets
cannot be maintained,
a minimum
clearance
of 24"
is required and the underside of the cabinets above
the cooktop
must be protected
with not less than
1/4" insulating
millboard
covered with sheet metal
not less than 0.0122" thick.
13" MAX. Depth of unprotected
overhead cabinets
2" MIN. Clearance
from cutout
to
side wall on the
right
of the unit
30" MIN.
Clearance
from
15" MIN. Height
countertop
to
countertop
to
unprotected
nearest
cabinet
on
overhead
either side of unit
surface
2" MIN. Clearance
from
cutout
to side wall on the
left of the unit
3

Advertisement

Table of Contents
loading