Orion StarMax 102mm EQ Instruction Manual page 19

Equatorial maksutov-cassegrain telescope
Hide thumbs Also See for StarMax 102mm EQ:
Table of Contents

Advertisement

Figure 4a
Figure 4a:
Using the 3mm
Allen wrench, turn the large
screw clockwise a small
amount, no more than 1/4 of
a turn. (Note, actual selected
alignment screw will vary.)
If the alignment screw is a large screw
First, using the 3mm Allen wrench, turn the large screw clock-
wise a small amount, no more than a 1/4 turn. (Figure 4a)
Now, with the 2mm Allen wrench turn the two adjacent small
screws (Figure 4b) counterclockwise no more than 1/4 turn.
Locate the small screw that is 180° opposite the first screw
(Figure 4c) and turn it clockwise no more than 1/4 turn.
Figure 5a
Figure 5a:
Using the 2mm
Allen wrench, turn the large
screw counterclockwise a small
amount, no more than 1/4 of a
turn. (Note: Actual selected
alignment screw will vary.)
If the alignment screw is a small screw
First, using the 2mm Allen wrench, turn the small screw
counterclockwise a small amount, no more than a 1/4 turn.
(Figure 5a)
Now, with the 3mm Allen wrench, turn the two adjacent large
screws (Figure 5b) clockwise no more than 1/4 turn.
Locate the large screw that is 180° opposite the first screw
(Figure 5c) and turn it counterclockwise no more than 1/4 turn.
Finishing Collimation
Once you have finished adjusting your telescope, you will
need to perform another star test (described earlier) to check
the collimation. If your telescope appears collimated after
star testing, it should not need adjustment again unless it is
roughly handled.
Figure
4b
Figure 4b:
Now, with the
2mm Allen wrench, turn the
two adjacent small screws
counterclockwise no more
than 1/4 turn.
Figure 5b
Figure 5b:
Now, with the
3mm Allen wrench turn the
two adjacent large screws
clockwise no more than
1/4 turn.
Figure 4c
Figure 4c:
Turn the small
screw that is 180° opposite
the first screw clockwise no
more than 1/4 turn.
Turn the two large screws adjacent to the small screw
(Figure 4d) counterclockwise no more than 1/4 turn.
Repeat the above steps until the front opening is centered in
the direction you wanted it to go. You may need to repeat this
(or the small screw adjustment process) with other screws in
order to align it in other directions.
Figure 5c
Figure 5c:
Turn the
large screw that is 180°
opposite the first screw
counterclockwise no more
than 1/4 turn.
Turn the two small screws adjacent to the large screw (Figure
5d) clockwise no more than 1/4 turn.
Repeat the above steps until the front opening is centered in
the direction you wanted it to go. You may need to repeat this
(or the large screw adjustment process) with other screws in
order to align it in other directions.
Repeat these two procedures as needed until the view
through the scope resembles Figure 2b.
If you have gone through this process and your telescope is
still out of collimation, please contact Orion customer sup-
port.You may need to return the telescope for repair (covered
on warranty for 1 year after purchase).
Figure 4d
Figure 4d:
Turn the two
large screws adjacent to the
small screw counterclockwise
no more than 1/4 turn.
Figure 5d
Figure 5d:
Turn the two
large screws adjacent to the
small screw clockwise no
more than 1/4 turn.
3

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

9824