Test Mode - Kenwood KDC-4047UA Service Manual

Table of Contents

Advertisement

■ Example
Key
A symbol "■" in the key column indicates that the key should be pressed and held.
Key
5
Disc Eject times display
■ 5
● How to enter the Test mode
Procedure
Press and hold the [1] key and [3] key and reset.
All lamps blinks when it is detected that the sub-clock resonator is disconnected.
When having started up in the Test mode, change the LINE MUTE inhibition time from 10 seconds to 1 second.
In the Test mode, do not write the detection information in the Data Flash ROM even if a DC Offset Error is detected.
Do not operate the DEMO mode in the Test mode, CD Mechanism Error Log Information Clear Mode, or DC Offset Error Detection Information
Clear Mode.
Also, when the source is STANDBY in the above mode, do not display DEMO ON/OFF switching items in the FUNCTION.
In the Test mode, the forced disc ejection operation is prohibited.
● How to clear the Test mode
Reset, Momentary power down, ACC OFF, Power OFF, Panel detached.

TEST MODE

Description of display
Description of display
E
J
C
N
T
X
SEARCH
SRC
BAND
RETURN
Procedure
KDC-4047UA/4047UG/4047UGY/4047UM
KDC-414UA/414UM/MP245U/U3046/U346/U4046
:
Disc Eject times display (Max. 65535 times).
X
X
X
X
While Disc Eject times is displayed, press and hold for 2
seconds or longer to clear Disc Eject times.
DISP
Note
Description
Description
EJECT
9