I AMP ADJUSTMENT / アンプ部調整
Confirmation of Idling Current of Main (1) P. C. B.
• Right after power is turned on, confirm that the voltage
across the terminals of R164 (Main Lch), R168 (Main
Rch), R181 (Center), R175 (Rear Lch), R177 (Rear
Rch), R416 (Rear Cch) are between 0.1mV and
10.0mV.
• If it exceeds 10.0mV, open (cutoff) R109 (Main Lch),
R116 (Main Rch), R136 (Center), R122 (Rear Lch),
R129 (Rear Rch), R403 (Rear Cch) and reconfirm the
voltage.
Attention
If the idle current exceeds 10.0mV after an amplifier
repair, first check for a defective component before
cutting the bias resistor.
• Confirm that the voltage is 0.2mV ~ 15.0mV after 60
minutes.
RX-V540/RX-V540RDS/HTR-5650/HTR-5650RDS/DSP-AX540
RX-V440/RX-V440RDS/HTR-5640/HTR-5640RDS/DSP-AX440
0.1mV ~ 10.0mV
(DC)
R164 (MAIN Lch)
R168 (MAIN Rch)
R181 (CENTER)
Cut off
カット
R109 (MAIN Lch)
R116 (MAIN Rch)
R136 (CENTER)
R122 (REAR Lch)
R129 (REAR Rch)
R403 (REAR Cch)
メイン (1) 基板のアイドリング電流の確認
● 電源投入直後、R164 ( MAIN Lch) 、R168 ( MAIN Rch) 、
R181 ( CENTER) 、R175 ( REAR Lch) 、R177 ( REAR
Rch) 、R416 (REAR Cch) の端子間電圧を測定し、
0.1mVから10.0mVの間であることを確認してくださ
い。
● 電圧が10mVを超えている場合は、R109 ( MAIN Lch) 、
R116 ( MAIN Rch) 、R136 ( CENTER) 、R122 ( REAR
Lch) 、R129 ( REAR Rch) 、R403 ( REAR Cch) をカット
し、電圧を再確認してください。
注意
パワーアンプ修理後に10.0mVを超えている場合は、抵
抗をカットする前に故障箇所を調べてください。
● 60分後、電圧が0.2mV∼15.0mVであることを確認して
ください。
0.1mV ~ 10.0mV
(DC)
R175 (REAR Lch)
R177 (REAR Rch)
R416 (REAR Cch)