&WARNING:
The air compressor
pump
and
shroud
are
designed
to allow for proper
cooling.
The ventilation
openings
on the compressor
are necessary
to maintain proper operating
temperature.
Do not place rags or other containers
on or near
these openings.
Place the air compressor on a flat surface resting on the rubber
feet and wheels.
ELECTRICAL
Refer to all safety instructions before using unit. Observe extension
cord safety instructions
if necessary. Always move the Auto/Off
switch (A) to the OFF position before removing the plug from the
outlet.
TRANSPORTING
When transporting the compressor
in a vehicle, trailer, etc., make
sure the tank is drained and the unit is secured with straps to prevent
tipping. Use care when driving to prevent tipping the unit over in the
vehicle. Damage can occur to the compressor or surrounding items
if the compressor is tipped.
LIFTING
Always use two people when lifting and lift
from the recommended
lift points (N). DO
NOT lift by wheels or shroud.
MOVING
_,CAUTION:
The wheels and handle
do
not provide adequate clearance, stability, or
support for pulling the unit up and down stairs
or steps. The unit must be lifted or pushed up
a ramp.
1. Grasp
handle
of compressor
and tilt
compressor back to rest on wheels.
_&WARNING: Risk of Unsafe Operation. Ensure proper footing and
use caution when rolling compressor so that unit does not tip or
cause loss of balance.
2. When location is reached slowly lower compressor to ground.
Always store compressor
in a vertical
position resting
on
the rubber bumpers and wheels.
PREPARATION
FOR
USE
WARNING: Do not operate this unit until you read this instruction
manual for safety, operation and maintenance instructions.
Pre-Start
Checklist
(Fig.
1)
1. Ensure the Auto/Off switch (A) is in the OFF position.
2. Plug the power cord into the correct branch circuit receptacle. See
Voltage and Circuit Protection
under Installation.
3. Ensure air tank is drained, see Draining
Air Tank
under
Maintenance.
4. Ensure the drain valve (H) is closed.
5. Ensure safety valve (G) is functioning properly, see Checking
Safety Valve under Maintenance.
6. Pull the regulator knob (D) out and turn counterclockwise until fully
closed. Ensure regulated pressure gauge reads 0 psi. Push knob
in to lock in place.
7. Attach hose and accessories.
NOTE: Always use a minimum
3/8" (9.5 mm) or greater air hose rated at 300 psi.
_&WARNING: Risk of unsafe operation. Firmly grasp air hose in hand
when installing or disconnecting to prevent hose whip.
_&WARNING: Risk of unsafe operation. Do not use damaged or worn
accessories.