2. Ensure the outlet being used has the same configuration as the
grounded plug. DO NOT USE AN ADAPTER.
3. Inspect the plug and cord before each use. Do not use if there
are signs of damage.
4. If these grounding instructions are not completely understood, or
if in doubt as to whether the compressor is properly grounded,
have the installation checked by a qualified electrician.
_,DANGER:
Risk of Electrical Shock. IMPROPER
GROUNDING
CAN RESULT IN ELECTRICAL
SHOCK.
* Do not modify the plug provided. If it does not fit the available
outlet, a correct outlet should be installed
by a quafified
electrician.
* Repairs to the cord set or plug MUST be made by a quafified
electrician.
Extension
Cords
If an extension cord must be used, be sure it is:
• a 3-wire extension cord that has a 3-blade grounding plug, and
a 3-slot receptacle that will accept the plug on the product
• in good condition
• no longer than 50 feet (15.2 m)
• 12 gauge (AWG) or larger.
(Wire size increases as gauge
number decreases. 10 AWG and 8 AWG may also be used. DO
NOT USE 14 OR 16 AWG.)
NOTICE:
Risk of Property
Damage.
The use of an undersized
extension cord will cause voltage to drop resulting in power loss
to the motor and overheating. Instead of using an extension cord,
increase the working reach of the air hose by attaching another
length of hose to its end. Attach additional
lengths of hose as
needed.
Voltage
and
Circuit
Protection
Refer to the Voltage and Minimum Branch Circuit Requirements
under Pump/Motor Specifications.
_CAUTION:
Certain
air compressors
can be operated
on a
15 amp circuit ff the following conditions are met.
*
Voltage supply
to circuit must comply
with the National
Electrical Code.
* Circuit is not used to supply any other electrical needs.
* Extension cords comply with specifications.
* Circuit is equipped with a 15 amp circuit breaker or 15 amp
time delay fuse. NOTE: If compressor is connected to a circuit
protected
by fuses, use only time delay fuses. Time delay
fuses should be marked "D" in Canada and "T" in the US.
If any of the above conditions cannot be met, or ff operation of the
compressor repeatedly causes interruption of the power, it may be
necessary to operate it from a 20 amp circuit. It is not necessary to
change the cord set.
Compatibility
NOTE: Always use an air line filter to remove moisture and oil vapor
when spraying paint.
£ocation
Place the air compressor
in a clean, dry and well ventilated area
at least 12" (30.5 cm) away from the wall or other obstructions that
will interfere with the flow of air. Keep the compressor away from
areas that have dirt and/or volatile fumes in the atmosphere. These
impurities may clog the intake filter and valves, causing inefficient
operation.