Program Your Schedule
The schedule is used with the Automatic mode. The
schedule controls the heating system to automatically
switch between the Comfort and Economy temperature
setpoints at the times you have programmed.
The schedule consists of 4 programs per day defined as
follows:
Programs
Setpoint
Time
Wake-up
Leave home
Back home
Night
i.
The programs' start time can be different for each day of the week.
To enter the programs' start time
To shorten programming, you simply have to enter the
start time for each program.
Press PGM.
Press DAY to select the day (hold for 3 seconds to
select all days of the week).
Temperature Control
The TH132 thermostat works differently than conventional
electromechanical thermostats.
It is equipped with a proportional integral adaptive (PIA)
controller which determines heating cycles by analyzing
the temperature behavior history within the room.
The PIA controller reduces temperature swings providing
accurate temperature control while increasing user com-
fort.
The controller determines the amount of power required
by the heating system to maintain the setpoint tempera-
ture.
When the heating system is activated, one of the following
icons is displayed:
1 to 20%
21 to 40%
41 to 60%
61 to 80% 81 to 100%
Note:
It is sometimes faster to program the same sched-
ule for the entire week and then to modify the exception
days.
Press PGM to select the program number (e.g. 1).
Press HOUR and MIN to set the start time.
Repeat steps 3 to 4 for remaining programs (e.g. 2, 3
and 4).
Press MODE/RETURN to exit.
i
Note:
After 60 seconds of inactivity, the thermostat will
automatically exit programming mode.
To clear a program time:
When you clear a program time entry, the TH132 will
maintain the temperature setpoint of the last executed
program until the beginning of the next program.
Repeat steps 1 to 3 above.
Press CLEAR to erase the time entry. The time por-
tion of the LCD indicates --:-- when the program is
inactive.
Press MODE/RETURN to exit.
Technical Specifications
Model: TH132 A / AF / F
Display
range: 32°F to 140°F (0°C to 60°C)
Setting range
: 40°F to 86°F (5°C to 30°C)
(ambient)
Setting range
: 40°F to 104°F (5°C to 40°C)
(floor)
Pre-programmed temperature
setpoints:
Comfort: A/AF: 68°F (20°C) and F: 82°F (28°C)
Economy: A/AF: 64°F (18°C) and F: 68°F (20°C)
Vacation: A/F/AF: 50°F (10°C)
Floor
limit: AF: 82°F (28°C)
Temperature resolution display
Storage:-4°F to 120°F (-20°C to 50°C)
Software: Class A
Controller: Electronic
Temperature
control: Proportional integral adaptive,
15-minute heating cycles
Programming
protection: Protected memory
Clock
protection: 2 hours
Size
(H/W/D): 3.3 x 3.1 x 0.5 in (83 x 79 x 13 mm)
Programming Example
Programs
MO
6:00
8:30
16:00 16:00 16:00 16:00 16:00 --:--
23:00 23:00 23:00 23:00 23:00 23:00 23:00
Comfort :
• Monday to Friday, between 6:00 and 8:30 and
between 16:00 and 23:00.
• Saturday and Sunday, between 6:00 and 23:00.
Economy :
• Monday to Friday, between 8:30 and 16:00 and
between 23:00 and 6:00.
• Saturday and Sunday, between 23:00 and 6:00.
To program this schedule
Press PGM.
Press and hold DAY for 3 seconds to select all days
of the week.
Press PGM to select program 1.
Set the time (6:00) using the HOUR and MIN buttons.
Warranty
AUBE TECHNOLOGIES INC. TWO (2) YEAR LIMITED WARRANTY
This product is guaranteed against workmanship defects
for a two-year period following the initial date of purchase.
During this period, AUBE Technologies Inc. will repair or
replace, at our option and without charge, any defective
product which has been used under normal conditions.
The warranty does not cover delivery costs and does not
apply to products poorly installed or randomly damaged
following installation.
This
warranty
cancels
manufacturer's express or implied warranty as well as any
other company commitment. AUBE Technologies Inc.
scale: 0.1°
cannot be held liable for related or random damages
following the installation of this product.
The defective product as well as the purchase invoice
must be returned to the place of purchase or mailed,
prepaid and insured, to the nearest shipping address.
Press PGM to select program 2.
Set the time (8:30) using the HOUR and MIN buttons.
TU
WE
TH
FR
SA
SU
Repeat step 4 for remaining programs:
6:00
6:00
6:00
6:00
6:00
6:00
program 3 (16:00) and program 4 (23:00).
8:30
8:30
8:30
8:30
--:--
--:--
When all programs are configured, press MODE/
--:--
RETURN to exit.
To erase programs 2 and 3 for Saturday and
Sunday
Press PGM.
Press PGM to select program 2.
Press DAY to select SAturday (SA).
Press CLEAR to erase the time (--:--).
Press DAY to select SUnday (SU).
Press CLEAR to erase the time (--:--).
Press PGM to select program 3.
Repeat steps 3 to 6.
Press MODE/RETURN to exit.
If you have any questions concerning the programming of
the TH132 programmable thermostat, call our technical
support team at:
705 Montrichard
Saint-Jean-sur-Richelieu
Quebec, Canada J2X 5K8
Tel.: (450) 358-4600
Toll Free: 1-800-831-AUBE
and
replaces
any
other
Fax: (450) 358-4650
Email: service@aubetech.com
For more information on our products, visit us at:
10 rue Ampère
95500 Gonesse
France
33 (0) 1 34 07 99 00
33 (0) 1 34 07 99 19
advaube@comintes.com
www.aubetech.com
® partner, Aube Technologies has
As an E
S
NERGY
TAR
determined that this product meets the E
S
NERGY
TAR
guidelines for energy efficiency.
26/08/2003
400-132-000-A

Advertisement

loading

This manual is also suitable for:

Th132aTh132fTh132afTh132 afTh132 aTh132 f