23
Venting
the
Dryer
(conf.)
Ductwork
Recommended
(10.2
cm)
(10.2 c:m)
Use only for
short run
installations
o
I
2
3
4
o
I
2
3
4
65 ft, (19,8 m)
55 ft. (16.8 m)
47 ft. (14,3 m)
36 ft. (11,0 m)
28 ft. (8.5 m)
55 ft. (16.8 m)
47 ft. (14.3 m )
41 ft. (12.5 m)
30 ft. (9,1 m)
22 ft, (6.7 m)
J
- _
NOTE
-.,
Deduct 6 ft. (1.8 m) for each additional
elbow. It is not
recommended
to use more than four 90° elbows.
Routing
and
Connecting
Ductwork
-- _
NOTE
Follow the guidelines
below to maximize drying
performance
and reduce lint buildup
and
condensation
in the ductwork,
Ductwork
and fittings
are NOT included
and must be
purchased separately.
. Use 4-inch (10.2 cm) diameter
rigid or semirigid
metal ductwork,
. The exhaust duct run should be as short as possible,
. Use as few elbow joints as possible,
. The male end of each section of exhaust duct must
point away from the dryer,
. Use duct tape on all duct joints,
. Insulate ductwork
that runs through
unheated
areas
in order to reduce condensation
and lint buildup
on
duct surfaces.
. Incorrect or inadequate
exhaust systems are not
covered by the dryer warranty.
Failures or poor
performance
caused by such exhaust systems will
not be covered by the dryer warranty.
Correct
Venting
Incorrect
Venting