Snmp - Siemens HiPath 3000 Administration Manual

Hide thumbs Also See for HiPath 3000:
Table of Contents

Advertisement

Administration via Local Phone
|
--- Admin
|
--- Network
|
--- Update Service (DLS)
|--- DLS address
|--- DLS port
|--- Contact gap
|
--- Secured
3.3.8

SNMP

The Simple Network Management Protocol is used by network management systems for mon-
itoring network-attached devices for conditions that warrant administrative attention. An SNMP
manager surveys and, if needed, configures several SNMP elements, e.g. VoIP phones.
OpenStage phones support SNMPv1.
There are currently 4 trap categories that can be sent by the phones:
Standard SNMP traps
OpenStage phones support the following types of standard SNMP traps, as defined in RFC
1157:
coldStart: sent if the phone does a full restart.
warmStart: sent if only the phone software is restarted.
linkUp: sent when IP connectivity is restored.
QoS Related traps
These traps are designed specifically for receipt and interpretation by the QDC collection sys-
tem. The traps are common to SIP phones, HFA phones, Gateways, etc.
Traps specific to OpenStage phones
Currently, the following traps are defined:
TraceEventFatal: sent if severe trace events occur; aimed at expert users.
TraceEventError: sent if severe trace events occur; aimed at expert users.
Data required
Trap sending enabled / Traps enabled: Enables or disables the sending of a TRAP mes-
sage to the SNMP manager.
Value range: "Yes", "No".
Default: "No".
A31003-S2010-M100-18-76A9
OpenStage HFA Family, Administration Manual
administration.fm
Administration
IP Network Parameters
3-25

Hide quick links:

Advertisement

Table of Contents
loading