Hydraulic System Maintenance; Servicing The Hydraulic; System - Toro 74413 Operator's Manual

With 48in or 52in turbo force side discharge mower
Hide thumbs Also See for 74413:
Table of Contents

Advertisement

Figure 54
1. Clevis pin in slot
2. Nut
3. Nut-Left hand thread
4. Adjustment bolt
5. Pump rod
7. Check where the control lever is relative to the
notch in the console (Figure 53). It should be
centered, allowing the lever to pivot outward
to the neutral lock position.
8. If adjustment is needed, loosen the nut and
jam nut against the yoke (Figure 54).
9. Apply slight rearward pressure on the motion
control lever, and turn the head of the
adjustment bolt in the appropriate direction
until the control lever is centered in the neutral
lock position.
Note: Keeping rearward pressure on the
lever will keep the pin at the end of the slot and
allow the adjustment bolt to move the lever to
the appropriate position.
10. Tighten the nut and jam nut (Figure 54).
11. Repeat on the opposite side of machine.
6. Double nuts
7. Jam nut
8. Yoke
9. Ball joint
Hydraulic System
Maintenance

Servicing the Hydraulic

System

Checking the Hydraulic Fluid
Fluid Type: Mobil 1 15W-50 synthetic motor oil or
equivalent synthetic oil.
Important: Use oil specified or equivalent.
Other fluids could cause system damage.
Hydraulic System Oil Capacity: 67 ounces (2.0 l)
Check the hydraulic fluid level:
• Before the engine is first started.
• After the first 8 operating hours.
• After every 25 operating hours.
Note: There are two ways of checking the
hydraulic oil. One is when the oil is warm and one
is when the oil is cold. The baffle inside the tank
has two levels depending if the oil is warm or cold.
1. Position the machine on a level surface and set
the parking brake.
2. Clean the area around filler neck of hydraulic
tank (Figure 55).
3. Remove the cap from the filler neck. Look
inside to check if there is fluid in the reservoir
(Figure 55).
4. If there is no fluid, add fluid to the reservoir
until it reaches the cold level of the baffle.
5. Run the machine at low idle for 15 minutes to
allow any air to purge out of the system and
warm the fluid. Refer to Starting and Stopping
the Engine in Operation, page 15.
6. Recheck the fluid level while the fluid is warm.
The fluid should be between cold and hot.
7. If required, add fluid to the hydraulic tank.
Note: The fluid level should be to the top
of the hot level of the baffle, when the fluid
is hot (Figure 55).
8. Install the cap on filler neck.
42