Omega Engineering CN3271 Series User Manual page 13

High-low limit alarm unit
Table of Contents

Advertisement

r 1
r 1 =Input Type and Range Value
r 1
r 1 r 1
=Input Type and Range Value
=Input Type and Range Value
=Input Type and Range Value
=Input Type and Range Value
0 = TC J
From
-100 to
1000
1 = TC K
From
-100 to
1370
2 = TC T
From
-200 to
3 = TC E
From
-100 to
4 = TC N
From
-100 to
1400
5 = TC S
From
-50 to
1760
6 = TC R
From
-50 to
1760
7 = TC B
From
0 to
1820
8 = TC L
From
-100 to
9 = TC U
From
-200 to
10 = TC G
From
0 to
2300
11 = TC D
From
0 to
2300
12 = TC C
From
0 to
2300
13 = TC Plat. II
From
-100 to
1400
14 = RTD Pt 100 From
-200 to
15 = Linear
From
0 to
16 = Linear
From
12 to
17 = Linear
From
0 to
18 = Linear
From
4 to
19 = Linear
From
0 to
20 = Linear
From
1 to
21 = Linear
From
0 to
22 = Linear
From
2 to
23 = TC J
From
-150 to
1830
24 = TC K
From
-150 to
2500
25 = TC T
From
-330 to
26 = TC E
From
-150 to
1470
27 = TC N
From
-150 to
2550
28 = TC S
From
-60 to
3200
29 = TC R
From
-60 to
3200
30 = TC B
From
32 to
3300
31 = TC L
From
-150 to
1650
32 = TC U
From
-330 to
1110
33 = TC G
From
0 to
4170
34 = TC D
From
0 to
4170
35 = TC C
From
0 to
4170
36 = TC Plat. II
From
-150 to
2550
37 = RTD Pt100 From
-330 to
1560
LHL-1-NEUTRO.pmd
10
r2 = Decimal Point Position
r2 = Decimal Point Position
r2 = Decimal Point Position
r2 = Decimal Point Position
r2 = Decimal Point Position
°C
(Available only for linear range r1 = 15 to 22)
_ _ _ _ .
_ _ _ _ .
°C
_ _ _ _ .
_ _ _ _ .
_ _ _ _ .
400
°C
_ _ _ . _
_ _ _ . _
_ _ _ . _
_ _ _ . _
_ _ _ . _
800
°C
_ _ . _ _
_ _ . _ _
_ _ . _ _
_ _ . _ _
_ _ . _ _
°C
_ . _ _ _
_ . _ _ _
_ . _ _ _
_ . _ _ _
_ . _ _ _
°C
°C
°C
r3 = Initial value of the readout scale
r3 = Initial value of the readout scale
r3 = Initial value of the readout scale
r3 = Initial value of the readout scale
r3 = Initial value of the readout scale
900
°C
(Available only for linear range r1 = 15 to 22)
600
°C
Range: From -1999 to 9999
°C
°C
°C
r4 = final value of the readout scale
r4 = final value of the readout scale
r4 = final value of the readout scale
r4 = final value of the readout scale
r4 = final value of the readout scale
°C
(Available only for linear range r1 = 15 to 22)
850
°C
Range: From -1999 to 9999
60
mV
60
mV
20 mA
r5 = Offset Adjustment
r5 = Offset Adjustment
r5 = Offset Adjustment
r5 = Offset Adjustment
r5 = Offset Adjustment
20 mA
Range: From -500 to 500
5
V
Offset value algebraically added to the measured
5
V
value.
10
V
10
V
°F
r6 = Time constant of the filter applied to
r6 =
r6 =
r6 =
r6 =
Time constant of the filter applied to
Time constant of the filter applied to
Time constant of the filter applied to
Time constant of the filter applied to
°F
the displayed value
the displayed value
the displayed value
the displayed value
the displayed value
750
°F
Range: From 0 (filter OFF) to 8 seconds.
°F
(First order filter with selected time constant.)
°F
°F
r7 = Alarm action on input fault.
r7 = Alarm action on input fault.
°F
r7 = Alarm action on input fault.
r7 = Alarm action on input fault.
r7 = Alarm action on input fault.
°F
When the instrument detects an input failure
°F
condition, the alarm will operate as in presence of:
°F
uP = as in presence of the full scale value.
°F
doun = as in presence of the initial scale value.
°F
°F
°F
C1 = Type of limit action
C1 = Type of limit action
C1 = Type of limit action
C1 = Type of limit action
C1 = Type of limit action
°F
10
19/04/2004, 15.07
= No decimal
= One decimal figure
= Two decimal figures
= Three decimal figures