Omega Engineering OM5-C User Manual page 51

Isolated signal conditioners
Table of Contents

Advertisement

Strain Gage Input Modules, Wide Bandwidth
FEATURES
● INTERFACES TO 100
THRU 10k , FULL-BRIDGE, HALF-BRIDGE,
OR QUARTER-BRIDGE STRAIN GAGES
● HIGH LEVEL VOLTAGE OUTPUTS
● 1500Vrms TRANSFORMER ISOLATION
● ANSI/IEEE C37.90.1-1989 TRANSIENT PROTECTION
● INPUT PROTECTED TO 240VAC CONTINUOUS
● FULLY ISOLATED EXCITATION SUPPLY
● 100dB CMR
● 10kHz SIGNAL BANDWIDTH
● 0.08% ACCURACY
● 0.02% LINEARITY
● 1 V/ C DRIFT
● CSA CERTIFIED, FM APPROVED, CE COMPLIANT
● MIX AND MATCH OM5 TYPES ON BACKPANEL
DESCRIPTION
Each OM5-WBS Strain Gage input module provides a single channel of
strain gage input which is filtered, isolated, amplified, and converted to a
high level analog voltage output (Figure 1). This voltage output is logic
switch controlled, which allows these modules to share a common analog
bus without the requirement of external multiplexers.
+EXC
Strain
4
Gage
+In
3
–In
2
–EXC
1
Backpanel
Term Block
FIGURE 1. OM5-WBS Block Diagram.
OM5-WBS
The OM5-WBS modules are designed with a completely isolated computer
side circuit which can be floated to 50V from Power Common, pin 16. This
complete isolation means that no connection is required between I/O
Common and Power Common for proper operation of the output switch. If
desired, the output switch can be turned on continuously by simply
connecting pin 22, the Read-Enable pin to I/O Common, pin 19.
The OM5-WBS can interface to full-bridge or half-bridge transducers with
a nominal resistance of 100
completion resistors (to 1mV at +10V excitation) allows use of low cost
half-bridge or quarter-bridge transducers (Figures 2, 3, 4). The 10kHz
bandwidth allows measurement of high speed processes such as vibration
analysis.
Strain Gage excitation is provided from the module by a very stable 10V
or 3.333V source. The excitation supply is fully isolated, allowing the
amplifier inputs to operate over the full range of the excitation voltage. This
feature offers significant flexibility in real world applications. Full scale
sensitivities of 2mV/V, 3mV/V or 10mV/V are offered as standard. With 10V
excitation, this results in 20mV, 30mV or 100mV full scale input range
producing 5V full scale output.
The input signal is processed through a pre-amplifier on the field side of
the isolation barrier. This pre-amplifier has a gain-bandwidth product of
5MHz and is bandwidth limited to 10kHz. After amplification, the input
signal is chopped by a proprietary chopper circuit. Isolation is provided by
transformer coupling, again using a proprietary technique to suppress
transmission of common mode spikes or surges. The module is powered
from +5VDC, 5%.
Special input circuits provide protection of the signal inputs and the
isolated excitation supply up to 240VAC.
4
LPF
Surge
6
Suppression
and
5
Protection
3
1
2
+V
Isolated
–V
Field-Side
Power
18
to 10k . A matched pair of bridge-
Isochopper™
Amplifier
LPF
Pat Pending
+V
–V
Isolated
Excitation
Isolated
Source
Computer-Side
Power
Power
Oscillator
20
V
OUT
19
I/O Common
22
RD EN\
17
+5V
16
Power
Common

Advertisement

Table of Contents
loading