1 Indication to the manual

This operating manual gives basic instructions which
are to be observed during installation, operation and
maintenance of the pump. It is therefore imperative
that this manual be read by the responsible personnel
and operator prior to assembly and commissioning. It
is always to be kept available at the installation site.
1.1
Identification of safety instructions in the
operating manual
Safety instructions given in this
compliance with which would affect safety are identi-
fied by the following symbol
Safety sign according with ISO 3864 - B.3.1
or where electrical safety is involved, with:
Safety sign according with ISO 3864 - B.3.6
Where non-compliance with the safety instructions
may cause a risk to the machine and it's function the
word
ATTENTION
is inserted.

2 Description of the Product

2.1
General description of the pump
Pumps of this type are one and two-stage centrifugal
pumps where the impeller is fixed on the driving shaft
extension. The TS pumps are fitted out with impellers
open on both sides to gain relative high pressure with
compact dimension of the pump unit. The pumps
should be protected against coarser impurities in the
coolants. Pump and motor form a compact and
space-saving unit.
Vertically mounted pumps are equipped with a mount-
ing flange. The pump end immerses into the tank and
the motor extends vertically above the tank.
BA6600
7 Operation ........................................................... 6
8 Servicing and Maintenance ............................... 6
9 Troubleshooting Guide ...................................... 7
10 Spare Parts ........................................................ 8
12 Disposal ............................................................. 8
13 WARRANTY ...................................................... 9
2.2
The immersion pumps of the series TS are suitable
for CNC machine tools featuring coolant supply
through the tool holder or driving spindle or equipped
with internally cooled tool within the limiting applica-
tion in accordance with table 1. Series TS are suitable
for filtered coolant only.
Limit of Application (Table 1)
manual non-
Type
Mediums
Kinetic viscosity
of the medium
Temperature of
medium
Particle-size in
the medium
min. delivery
volume
Dry running
Motor cycle
time per hour
Ambient
temperature
Set-up altitude
The pumps are to be operated within their design
limits.
approved. The manufacturer is not responsible for any
damages resulting from use of the pumps in such
applications.
04/2015
Edition
Intended use
TS12...15
Coolant, cooling- and cutting-oils
...200 SSU (...45 mm
30 ... 175 °F (0 ... 80 °C)
(
.... 300°F (.... 150 °C) as special
make)
0.08 Inch (2 mm) TS12...15
0.12 Inch (3 mm) TS21...24
1% of Q max.
The pumps are not suitable for dry
running.
Motors less 4.0 HP (3 kW) max. 200
104 °F (40 °C)
3280 ft (1000 m)
ATTENTION
Applications outside of these limits are not
TS21...24
2
/s)
Page 2 of 9