Characteristic Curve Temperature Sensor Outdoor Unit; Characteristic Curve Temperature Sensor Indoor Unit - Dimplex LAW 6IMR Installation And Operating Instructions Manual

Split air-to-water heat pump with hydrotower
Table of Contents

Advertisement

Available languages

Available languages

9.4 Characteristic curve temperature sensor outdoor unit

NTC - 10
-20
-15
Temperature in °C
k
105
80,2
25
26
Temperature in °C
k
10,0
9,57
NTC - 5
-20
-15
Temperature in °C
k
52,7
38,9
25
26
Temperature in °C
k
5,00
4,78
NTC - 200
1
5
Temperature in °C
k
525,00
448,00
70
75
Temperature in °C
k
43,73
37,35

9.5 Characteristic curve temperature sensor indoor unit

9.5.1 Sensor characteristic curves
-20
-15
Temperature in °C
NTC-2 in k
14,6
11,4
NTC-10 in k
67,7
53,4
15
20
25
30
35
2,9
2,4
2,0
1,7
1,4
14,9
12,1
10,0
8,4
7,0
The temperature sensors to be connected to the heat pump man-
ager must correspond to the sensor characteristic curve illus-
trated in Fig.9.1 on pag. 17. The only exception is the outdoor
temperature sensor included in the scope of supply of the heat
pump (see Fig.9.2 on pag. 17)

















$X‰HQWHPSHUDWXU >ƒ&@
Fig. 9.1: Sensor characteristic curve NTC-10
www.dimplex.de
Air sensor (outdoor unit)
-10
-5
-2
0
58,2
44,0
37,4
33,6
28
30
32
34
8,76
8,04
7,38
6,78
Pipe-mounted sensors (outdoor unit)
-10
-5
-2
0
29,1
22,0
18,7
16,8
28
30
32
34
4,38
4,02
3,69
3,39
Hot gas sensor (output compressor)
10
15
20
25
326,00
294,33
242,20
200,00
80
85
90
95
32,20
28,16
24,60
21,37
-10
-5
0
5
10
8,9
7,1
5,6
4,5
3,7
42,3
33,9
27,3
22,1
18,0
40
45
50
55
60
1,1
1,0
0,8
0,7
0,6
5,9
5,0
4,2
3,6
3,1








452162.66.04 · FD 9606
2
5
10
15
30,3
25,9
20,2
15,8
36
38
40
50
6,24
5,74
5,30
3,59
2
5
10
15
15,1
13,0
10,1
7,92
36
38
40
50
3,12
2,87
2,65
1,79
30
35
40
45
167,57
138,03
133,80
98,00
100
105
110
115
18,50
16,60
14,50
13,30




















$X‰HQWHPSHUDWXU >ƒ&@
Fig. 9.2: Sensor characteristic curve NTC-2 according to
DIN 44574
Outdoor temperature sensor
9.5.2 Mounting the outdoor temperature
sensor
The temperature sensor must be mounted in such a way that all
weather conditions are taken into consideration and the meas-
ured value is not falsified.
On the external wall of a heated room used as living space,
if possible on the north or north-west side of the building
Do not install in a "sheltered position" (e.g. in a wall niche or
under a balcony)
Not in the vicinity of windows, doors, exhaust air vents,
external lighting or heat pumps
Not to be exposed to direct sunlight at any time of year
Sensor lead: Max. length 40 m; min. core cross-section
0.75 mm²; external diameter of the cable 4-8 mm.
LAW 6IMR - LAW 14ITR
18
20
22
24
13,8
12,5
11,4
10,5
60
70
80
90
2,49
1,76
1,27
0,93
18
20
22
24
6,88
6,27
5,72
5,23
60
70
80
90
1,24
0,88
0,64
0,47
50
55
60
65
82,00
64,50
59,00
50,71
120
130
12,80
10,80








EN-17

Hide quick links:

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

Law 14itrLaw 9imrLaw 14imr

Table of Contents