Install the processor socket cover on the failed system board.
9.
Install the system board assembly (on page 31).
10.
Install the DIMMs.
11.
If removed, install the expansion board.
12.
Install the chassis cover (on page 28).
13.
Connect the power cord to the server.
14.
Connect the power cord to the AC power source.
15.
Press the Power On/Standby button.
16.
The server exits standby mode and applies full power to the system. The system power LED changes
from amber to green.
After you replace the system board, you must re-enter the server serial number and the product ID.
During the server startup sequence, press the F9 key to access RBSU.
1.
Select the Advanced Options menu.
2.
Select Service Options.
3.
Select Serial Number. The following warning appears:
4.
Warning: The serial number should ONLY be modified by qualified service
personnel. This value should always match the serial number located on the
chassis.
Press the Enter key to clear the warning.
5.
Enter the serial number and press the Enter key.
6.
Select Product ID. The following warning appears:
7.
Warning: The Product ID should ONLY be modified by qualified service
personnel. This value should always match the Product ID located on the
chassis.
Enter the product ID and press the Enter key.
8.
Press the Esc key to close the menu.
9.
Press the Esc key to exit RBSU.
10.
Press the F10 key to confirm exiting RBSU. The server automatically reboots.
11.
Removal and replacement procedures 60