Suction piping thermistor
J5
system malfunction (Out-
door unit)
Outdoor heat exchanger
distributor liquid piping
J6
thermistor malfunction
(Outdoor unit)
Outdoor heat exchanger
condenser / evaporator
J7
thermistor malfunction
(Outdoor unit)
Liquid piping thermistor
J8
system malfunction (Out-
door unit)
Gas piping thermistor
J9
malfunction (cooling)
(Outdoor unit)
Discharge piping pres-
JA
sure sensor system mal-
function (Outdoor unit)
Suction piping pressure
JC
sensor system malfunc-
tion (Outdoor unit)
Inverter system malfunc-
L1
tion (Outdoor unit)
Reactor thermistor mal-
L3
function (Outdoor unit)
Overheated heat-radiat-
L4
ing fin (Outdoor unit)
Instantaneous overcur-
L5
rent (Outdoor unit)
Electric thermal (Outdoor
L8
unit)
Stall prevention (Outdoor
L9
unit)
Transmission malfunction
between inverter and out-
LC
door control unit (Outdoor
unit)
Open-phase (Outdoor
P1
unit)
DCL sensor system mal-
P3
function (Outdoor unit)
Heat-radiating fin thermis-
P4
tor malfunction (Outdoor
unit)
DC output current sensor
P6
system malfunction (Out-
door unit)
Capacity setting failure
PJ
(Outdoor unit)
Suction piping tempera-
U0
ture abnormal (Outdoor
unit)
Reverse phase (Outdoor
U1
unit)
Power voltage malfunc-
U2
tion (Outdoor unit)
English
Abnormal stop is applied
depending on the model or
condition.
Abnormal stop is applied
depending on the model or
condition.
Abnormal stop is applied
depending on the model or
condition.
Inverter cooling failure.
The compressor engines and
turbines may be experiencing
a ground fault or short circuit.
The compressor engines and
turbines may be overloaded
and disconnected.
The compressor may be locked.
Abnormal stop is applied
depending on the model or
condition.
Capacity setting adapter or
capacity data error, or discon-
nection of the capacity setting
adapter, failure to connect the
adapter, or the capacity is not
set to the data-retention IC.
The refrigerant may be insuffi-
cient.
Abnormal stop is applied depend-
ing on the model or condition.
Reverse two phase of L1, L2
and L3 leads.
The inverter open-phase or
main circuit condenser may
be malfunctioning.
Abnormal stop is applied
depending on the model or
condition.
Transmission error
U4
(between indoor and out-
UF
door units)
Transmission error
U5
(between indoor and
remote controller units)
Transmission error of the
U7
inverter module
Transmission error
between main and sub
U8
remote controllers (sub
remote controller mal-
function)
UA
Field setting error
Transmission error
(between indoor unit and
UE
centralized remote con-
troller)
Remote controller
UC
address setting error
Accessory equipment
UJ
transmission error
CAUTION
After test operation is completed, check the items mentioned in
the clause 2 "2. Items to be checked at delivery" on page 3.
If the interior finish work is not completed when the test opera-
tion is finished, for protection of the air conditioner, ask the cus-
tomer not operate the air conditioner until the interior finish work
is completed.
If the air conditioner is operated, the inside of the indoor units
may be polluted by substances generated from the coating and
adhesives used for the interior finish work and cause water
splash and leakage.
To the operator carrying out test operation
After test operation is completed, before delivering the air con-
ditioner to the customer, confirm that the control box lid is
closed.
In addition, explain the power supply status (power supply ON/
OFF) to the customer.

13. WIRING DIAGRAM

(Refer to Fig. 40)
1
(NOTE 9)
3
INDOOR UNIT
5
(NOTE 5)
WIRED REMOTE CONTROL-
7
LER (OPTIONAL ACCES-
SORY) (NOTE 7)
IN CASE OF SIMULTANEOUS
9
OPERATION SYSTEM (NOTE
6)
11 INDOOR UNIT (SLAVE)
13 TO OUTDOOR UNIT
15 CLASS
Wiring error between indoor
and outdoor unit. Or Indoor
and outdoor Printed Circuit
Board failure.
Transmission between indoor
unit and remote controller is
not performed properly.
System setting error of the
simultaneous on/off multi-split
type.
Abnormal stop is applied
depending on the model or
condition.
2
TO OUTDOOR UNIT (NOTE 3)
4
(NOTE 5)
CENTRAL REMOTE CON-
6
TROLLER (NOTE 4)
WIRELESS REMOTE CON-
TROLLER (RECEIVER/DIS-
8
PLAY UNIT)
(OPTIONAL ACCESSORY)
10 INDOOR UNIT (MASTER)
12 REMOTE CONTROLLER
14 CONTROL BOX