All rangetops with Standard Burner Configuration
In case of combustible construction, an additional minimum clearance of
6" (150 mm) on each side is necessary. Ensure local codes are observed.
Position
1) The support base must have a minimum thickness of ³/₄" (19.05 mm).
At the rear right of the support base, a cut-out of 5 1/8" x 7 1/8" (130 mm x 80 mm) (gas
connection) is provided, and, at the rear left, a cut-out of 4 6/8" x 1 9/16" (120 mm x 40
mm) (electrical connection).
Dimensions
13" (330 mm)
18" (457 mm)
7¹/₂" (190.5 mm)
10" (254 mm)
Dimensional drawings
Description
Maximum depth of top cabinet
Minimum distance to bottom edge of
top cabinet
Distance between the top edge of the
countertop and the top edge of the
support base
Minimum distance to combustible sur-
faces
1)
Support base
41