Download Print this page

Advertisement

Quick Links

Air Conditioner

Problem Solver ..............................l4
More questions ?...call
Operating Instrudions, ~ps
Air Direction ....................................................5
Installation
Electrical Requirements ...............................7
: . : . : . : . : . 4 . : ::<::. : :. : <. :
Consumer Services
..................15
GE Appliances

Advertisement

loading

Summary of Contents for GE AED22

  • Page 1: Air Conditioner

    Problem Solver ......l4 More questions ?...call Operating Instrudions, ~ps Air Direction ............5 Installation Electrical Requirements .......7 : . : . : . : . : . 4 . : ::<::. : :. : <. : Consumer Services ....15 GE Appliances...
  • Page 2 Cheek the Problem Solver sation your phone number): of this guide. It lists causes of Consumer Affairs minor operating problems that you GE Appliances can correct yourself. Appliance Park Serial Numbr Louisville, KY 40225 Use these numbers in any correspondence or service calls concerning your air conditioner.
  • Page 3 Keep the air filter clean. Keep furnace floor registers and cold air returns closed. Cold air can easily escape through them. For most efficient cooling, keep the Ventilation Control in the CLOSED position except when you Don’t let drapes or fimiture block the front of the want to exhaust air, smoke or odors from the room.
  • Page 4 CLOSED OPEN VENTILATION SELECTOR THERMOSTAT Selector Stitch OFF turns air conditioner off. When you turn the Thermostat When you move the Ventilation Control to the desired setting, the thermostat will automatically is closed and only the air inside the speed operation without cooling. control the temperature of the room will be circulated and indoor air.
  • Page 5 For Normal Coobg For Maximum Coohg 1. Set the Selector Switch at Set the Energy Saver Switch at 1. Set the Selector Switch at HIGH COOL. HIGH COOL. fan operation or at SAVE position 2. Set the ~ermostat Control at the 2.
  • Page 6 If extremely soiled, it Wash the cabinet with mild soap or detergent and may need to be steam cleaned, a service available lukewarm water. through your GE service outlet. Air Ftiter Vacuum the filter on the dusty side to remove light dust. Wash...
  • Page 7 OWNER: Keep these instructions for future use. Electrical HOW ~CONNECTELEC~lC~ The 230/20~ok models require their own single FOR PERSONAL SAFm THIS APPLIANCE branch circuit supp~ing 230/20%olt a.c., protected with a time delay fuse or circuit breaker. This is recommended for best performance and to prevent The 11*oR models require a 115/120volt a.c., 60 possible fire hazard from overheating wires.
  • Page 8 Seal Window Sash Foam Top Rail Gasket Frame Assembly (right) Screw Filler Side ~etainer Panel Type C Screws , and Locknuts ‘ ‘ -m Type F Type D Type Type A Type B Type C Window support $, Sill Angle Bracket + Type D Bolt ~ Standard doubl~hung window with actual opening width and minimum vertical opening.
  • Page 9 A l/2’’ clearance below the window stool is required. If the storm window frame does not allow this clearance, attach a 1 Yz” or 2“wide strip of wood along the entire length of the window opening, flush with the back side of the stool, or remove the storm window for the air conditioning season.
  • Page 10 3. ASSEMBLE WINDOWFILLER ANELS 3. Shift cabinet left or right as needed to line up center of cabinet on center line marked on stool. Plastic Frame 2. Slide the “ section of the window filler panel into the panel retainer on the side of the cabinet as shown above.
  • Page 11 3. Reinstall inlet grille (see Care and 2. Attach right angle safety lock with Type B Cleaning section). screw as shown. with front edge of rail and in contact with (continued next~ge) side seals.
  • Page 12 2. PREMRE WE CABINfl The cabinet may be installed through the wail in both existing buildings and new construction. The side louvers must project on the outdoor 2. With caulking compound or electrical tape, side of the wall. seal 10 holes provided in cabinet for top rail The room side of the cabinet must project into and side retainers not used in this installation.
  • Page 13 3. lN~ALL tiBINfilN MIL. (continued) Be sure handle at bottom of unit is up. Then Iifi 4. Caulk all four sides on the outdoor side of chassis and carefully slide it into cabinet. Do not cabinet to prevent moisture from getting push on controls or finned coils.
  • Page 14 USE THIS PROBLEM SOLVER GE Answer CenteP S00.626.2000...
  • Page 15 With the purchase ofyournew GE appliance, receive the mswce that ifyou ever need /dome Repairsern=a AGE consumer service professional will provide expert repair service, scheduled at a time that’s convenient for you. Many GE Consumer Service convenience (7:00 a.m. to 7:00 p.m. weekdays, 9:00 a.m. to 2:00 p.m. Saturdays).
  • Page 16 Staple sales slip or cancelled check YOUR GE ROOM AIR CONDmONER here. Proof of original urchase date is needed to obta n semice under warran~. WHAT IS COVERED FULL ONE-YEAR WARRANTY This warranty is extended to the original purchaser and any...

This manual is also suitable for:

Aem14Aem23Aem15Climatiseur aem18*