4. Functions
Repeat
You can specify a repeat count to perform sampling for a specified number of times.
Memory must be set to ring format if a number of repetitions is to be specified.
(The number of repetitions cannot be specified for FIFO memory format.)
The number of repetitions is set by software and sampling is repeated for the specified number of times.
You can also specify that operation continue indefinitely. If set to repeat indefinitely, analog output
operation is stopped by outputting an analog output stop command by software.
Setting data
Use a software command to save the data in memory.
The figure below shows the relationship between the conversion data stored in memory and the sampling
count and conversion channels.
The procedure for setting the conversion data is different depending on the memory format being used.
-
Procedure for FIFO format
When using FIFO format, setting data to memory is always performed from the most recent data.
New data can be added during conversion.
54