GENERAL POINTS

The.water.heater.with.smooth-tube.heat.exchanger.can.be.connected.to.each.gas.or.oil.furnace.or.to.a.solar.system..The.position.of.the.heat.
exchangers.provides.complete.heating.of.the.water.in.the.accumulator.
The.tank.is.protected.by.an.enamel.covering.giving.protection.up.to.850°C,.in.accordance.with.the.requirements.of.DIN.4753.
The.water.heater.must.be.installed.by.an.approved.installer,.in.an.area.that.is.protected.against.freezing..Enamelled.tanks.are.suitable.for.nor-
mal.domestic.hot.water..Important:.the.electrical.connections.are.vital.to.prevent.corrosion.(iron,.copper).
Unused.connections.must.be.blocked..The.directives.in.force.and.the.instructions.from.the.local.water.service.as.well.as.DIN.standards.must.
be.followed.
The.tank.is.linked.to.the.hydraulic.distribution.network.via.a.cold.water.connection.and.to.usage.points.via.a.hot.water.connection.
If.hot.water.is.taken.from.a.usage.point,.cold.water.then.enters.the.reservoir.where.it.is.heated.to.the.temperature.set.using.the.thermostat.
(not.provided.with.the.product).
GB
It.is.advisable.to.maintain.the.water.temperature.between.60°.and.65°C,.as.this.guarantees.the.best.performance.for.the.unit.and.ensures.the.
following:
. .
-..Maximum.level.of.hygiene,
. .
-..Maximum.limit.for.thermal.loss,
. .
-..Limiting.the.formation.of.limescale.deposits.
Special features.:
. -.High.performance.coils:.high.heating.power.
. -.Maximum.operating.pressure:.see.technical.data.
. -.Temperature.display.
. -.Adjustable.feet.for.better.positioning.
. -.Protection.against.corrosion.using.magnesium.anodes.
. -.Outer.finish:.white.painted.sheet.steel.
. -.Heat.insulation:.expanded.polyurethane.foam.

INSTALLATION

Installation instructions
ONLY QUALIFIED PERSONNEL ARE AUTHORISED TO PERFORM THIS OPERATION, OTHERWISE THE WARRANTY WILL BECOME VOID
The.information.given.below.determines.the.validity.of.the.warranty.
1..The.installation.must:
a..Be.installed.by.a.qualified.installer..You.must.conform.to.current.national.standards..It.is.necessary.to.respect
. the.instructions.for.the.water.heater,
b..Provide,.when.necessary,.a.pressure.reducer.for.inlet.water,.(pressure.>.4,5.bar).
c..The.system.is.required.to.have.a.safety.assembly.(maximum.calibration:.7.bar).which.must.be.installed
with.the.unit.in.a.location.where.there.is.no.possibility.of.freezing.
..The.storage.temperature.must.remain.below.90°C
3..To.prevent.corrosion,.the.anodes.must.be.checked.every.1.months,.however.in.areas.with.especially.aggressive.water,.inspections. .
. must.be.carried.out.every.6.months;.if.the.anode.has.been.destroyed,.it.must.be.replaced..
4..It.is.recommended.that.the.generator.be.installed.as.close.as.possible.to.the.boiler;.in.all.cases,.it.is.important.that.the.connection.piping.is..
. insulated.