Philips TH-P19A Service Manual page 41

19" tft lcd colour monitor
Table of Contents

Advertisement

GENERAL PRODUCT SPECIFICATION
6.0
Environmental characteristics
The following sections define the interference and
susceptibility condition limits that might occur
between external environment and the display device.
6.1
Susceptibility of display to external environment
Operating
- Temperature : 5 to 45 degree C
- Humidity
- Altitude
- Air pressure : 700-1100 mBAR
Storage
- Temperature : -20 to 60 degree C
- Humidity
- Altitude
- Air pressure
6.2
Transportation tests
Standard
Normal
drop
Sequence
test
Cold
drop
Sequence
test
(For ref.)
Vibration
Test
1
TFT XGA LCD CMTR
TYPE: EG3S50/91
BRAND: THUNIS
2004-11-04
Kevin Chen
: 20% ~ 80%
: 0-12,000 feet
: 5% ~ 95% ( < 40
: 0-30,000 feet
: 300-1100 mBAR
Height
91.4 cm
1 corner ,3 edges, 6 faces
Test
Electrical function ok
Result
Mechanical function ok
No serious damage on set appearance
Height
91.4 cm
1 corner ,3 edges, 6 faces(-10deg C x 16 hrs)
Test result
Electrical function ok
Mechanical function ok
No serious damage on set appearance
(Room temp -10 , humidity 70 %)
Sequence
5~200Hz, 1.05g, 30min. for Each axis (X, Y, Z)
Test
Electrical function ok
Result
Mechanical function ok
No serious damage on set appearance
2004-11-04
)
THUNIS
8639 000 16042
12
590
11
41
TH - P19A
202P Gs3 CM25

Advertisement

Table of Contents
loading

Table of Contents