Download Print this page

System Settings - Bosch DVA-12T Quick Installation Manual

Raid subsystem
Hide thumbs Also See for DVA-12T:

Advertisement

50
en | Delivery Status
2.1.2

System Settings

Menu
Configuration Parameters/Communication
LAN 0/LAN 1
IP Address LAN 0
Subnet LAN 0
IP Address LAN 1
Subnet LAN 1
Configuration Parameters/Caching
Write-Back Cache
Optimization
Periodic Cache Flush Time (sec)
Configuration Parameters/Host Side
Maximum Queued I/O Count
LUNs per Host ID
Maximum Number of Concurrent Host-LUN
Connection
Number of Tags Reserved for each Host-LUN
Connection
Peripheral Device Type
Peripheral Device Qualifier
Device Supports Removable Media
LUN Applicability
Cylinder/Head/Sector Ranges
Login Authentication with CHAP
Configuration Parameters/Drive Side
Disk Access Delay Time (sec)
Drive I/O Timeout (sec)
Maximum Tag Count
Periodic Drive Check Time (sec)
Periodic SAF-TE/SES Device Check Time
(sec)
Periodic Auto-Detect Failure Drive Swap
Check Time (sec)
Drive Predictable Failure Mode (SMART)
Auto-Assign Global Spare Drive
Drive Spindown Idle Delay Period (sec)
Drive Delayed Write
Configuration Parameters/Disk Array
Rebuild Priority
Verification on LD Initialization Writes
Verification on LD Rebuild Writes
Verification on Normal Drive Writes
F.01U.027.801 | V5 | 2010.06
DVA-12T
Static IP Address
192.168.0.100
255.255.255.0
192.168.0.100
255.255.255.0
Enabled
Sequential I/O
30
1024
32
1024
4
No Device Present (Type = 0x7F)
Connected
Disabled
All Undefined LUNs
Variable/Variable/Variable
Disabled
25
7 (Default)
4
1
30
5
Detect Only
Enabled
Disabled
Disabled
Normal
Disabled
Disabled
Disabled
Quick Installation Guide
RAID Subsystem DVA-12T
Bosch Sicherheitssysteme GmbH

Advertisement

loading