Napoleon EPI 1101 Installation And Operating Instructions Manual page 24

Table of Contents

Advertisement

Available languages

Available languages

24
7.7
SECONDARY AIR MANIFOLD REPLACEMENT
At the end of each burning season inspect the secondary air manifold for warping or deterioration. Replace if
necessary. At this time also check that the door gasket is not worn, frayed or loose. Replace with 1/2" (13mm)
EN
high density fi breglass rope if necessary. Check the airwash gasket located inside the appliance above the door,
replace if deteriorated. Contact your Napoleon dealer for specifi c type and size of the materials required.
NOTE: Do not operate appliance if the manifold, airwash shield or fi bre baffl e is deteriorated or missing.
B
E
W415-1469 / A / 06.14.16
To remove the secondary air manifold follow these instructions:
A.
Remove insert from the fi replace.(See Sections 4.0
to 4.1 for vent information)
B.
Remove the 9 screws securing the top outer shell.
Set aside.
C.
Remove the 6 screws securing the rear outer shell.
Set side.
D.
Remove the rear bricks, then remove the baffl es.
E.
Remove the 2 nuts and bolts securing the secondary
air manifold in place.
F.
Remove the secondary air manifold and gasket.
X9
X2
C
E
F
SIDE VIEW
X6